Descargar Imprimir esta página

Crafstman 919.167280 Manual Del Propietário página 16

Publicidad

Idiomas disponibles

Idiomas disponibles

6.
After the water has been drained,
close the drain valve (clockwise).
The air compressor can now be
stored.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, the
reinstalled.
Air Filter
Inspection
and
Replacement
Risk of Burns.
Compressor
head
and cylinder
sleeve are very hot. Do
not touch. Allow compressor
to cool
prior to servicing.
A dirty air filter will not allow the
compressor to operate at full
capacity.
Keep the air filter clean at
all times.
1.
Remove the air filter and make
sure it is clean.
IMPORTANT:
Do not operate the
compressor
with the air filter re-
moved.
2.
If dirty, rinse air filter with warm
water and squeeze dry.
3.
Replace air filter.
NOTE: If the air filter is extremely dirty
it will need to be replaced. Refer to
the "Repair Parts" for the correct part
number.
Air Compressor
Pump
Intake
and Exhaust
Valves
Once a year have a Trained Service
Technician check the air compressor
pump intake and exhaust valves.
A16751
16-ENG

Publicidad