3. Operation
3.6.2 Air distribution
Air distribution
M-NET address
Identify unit Check button
Input display: SELECT
Address
Check
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Air distribution
M-NET address
Auto vane
Direct/Indirect
Direct/Indirect setting
Select: SELECT
Cur.
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Direct
horizontal → swing
Cooling
Heating
keep downward
1 Select the M-NET address for the
units to whose vanes are to be
fi xed, with the [F2] or [F3] button,
and press the [SELECT/HOLD]
button.
Press the [F4] button to confi rm the
unit.
The vane of only the target indoor
unit is pointing downward.
2 Select the menu with the [F4] but-
ton.
Default → Area → Direct/Indirect
→ Default...
Default: The vanes move the same
as during normal operation.
During cooling mode, all of the
vanes move to the horizontal air-
fl ow direction.
During heating mode, all of the
vanes move to the down airfl ow
direction.
Area: The vanes move to the down
airfl ow direction toward areas with
a high floor temperature during
cooling mode and toward areas
with a low fl oor temperature dur-
ing heating mode. Otherwise,
the vanes move to the horizontal
airfl ow direction.
Direct/Indirect: The vanes auto-
matically move relative to the areas
where persons are detected.
The vanes operate as indicated in
the following table.
Vane setting
Indirect
keep horizontal
downward → horizontal
Direct/Indirect setting
:
Direct
: Indirect
: Indirect
: Direct
Select: SELECT
Angle
Outlet
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
■
i-See button (Wireless remote controller)
1 Each time
is pressed during operation, the setting changes in
the following order: OFF → Direct → Indirect.
Display
Setting
OFF
Direct
When the setting is changed from OFF to Direct or Indirect, the vane setting
changes to "Auto". This setting is applied collectively to all of the vanes.
3 When Direct/Indirect is selected,
set each air outlet.
Select the air outlet with the [F1] or
[F2] button, and change the setting
with the [F4] button.
After changing the settings for all of
the air outlets, press the [SELECT/
HOLD] button to save the settings.
* In order to enable this function,
the airfl ow direction must be set
to "Auto".
Indirect
13
en