8 Set-up
8.1 Setting aid
For easy and reliable installation the sensor features an optical setting aid to
visualise the enable zone�
0
> 5 s
Signal
Power
1: close zone
2: enable zone
8.2 Determine the enable zone
When the setting aid is active, the enable zone can be determined by moving the
target (or the sensor if the target is fixed)�
0
Signal
Power
1: close zone
2: enable zone
30
30
Signal
Signal
Power
Power
The setting aid is activated by
placing a metal object in front of the
fail-safe sensor (close range)�
After approx� 5 s the yellow LED
starts to flash: the setting aid is
active�
mm
While this mode is active, the output
remains in the safe state ("0")�
As soon as the target enters the en-
able zone, the yellow LED goes out�
If the target is just outside the enable
zone in either direction the LED
starts to flash again�
mm
UK
9