Maintenance and care
Troubleshooting table
Trouble
Red Charger light flashes or does not light up
Unit will not turn on
Unit does not run when turned on
Running time is too short
Unit runs, but doesn't blow or is weak
Unit vibrates excessively
 Checking and maintenance requires specialist knowledge. If you are unable to check and maintain the product or deal with a
fault yourself, consult your ECHO dealer. Do not attempt to dismantle the product.
 Consult your dealer in the event of a problem that is not covered in the table above, or other such concerns.
 For spare parts and consumables, please use only genuine parts and designated products and components. Using parts from
other manufacturers or non-designated components may result in a malfunction.
Cause
 Plug not connected to power
outlet
 Battery pack not installed prop-
erly
 Obstructed connection
 Fault in the charger
 Fault in the battery pack
 Battery pack not installed prop-
erly
 Battery pack discharged
 Battery pack outside accept-
able temperature range
 Battery pack outside accept-
able temperature range
 Unit electronics too hot
 Battery pack discharged
 Blower pipe clogged
 Blower pipe loose
 Blower pipe damaged
 Air inlet clogged
 Fault in the fan
 Fault in internal parts
22
Solution
 Plug in the charger
 Check the battery pack installation
 Reinstall battery pack again after
removing obstructions from con-
nection
 Consult your ECHO dealer
 Consult your ECHO dealer
 Check the battery pack installation
 Charge the battery pack
 Remove the battery pack and al-
low to cool
 Remove the battery pack and al-
low to cool
 Turn unit off and allow to cool
 Charge the battery pack
 Unclog pipe
 Tighten pipe
 Replace pipe
 Unclog air inlet
 Consult your ECHO dealer
 Consult your ECHO dealer