How to Use Your Unit
How to Stop:
1.
Set the On/Auto/Off
lever to "OFF".
Before
Starting
Break-in
Procedure
_
Serious damage may result if the
following break-in instructions
are
not closely followed.
This procedure is required before the air compressor
is put into service and when the check valve or a
complete compressor
pump has been replaced.
1.
Make sure the On/Auto/Off
lever is in the "OFF"
position.
NOTE: If quick connect is installed, pull coupler back
until it clicks to prevent air from escaping through the
quick connect.
.
.
Switch
Plug the power cord into the correct branch circuit
receptacle. (Refer to Voltage and Circuit
Protection paragraph in the Installation section of
this manual.)
Open the drain valve
fully (counter-clock-
wise) to permit air to
escape and prevent air
pressure build up in
the air tank during the
break-in period.
4.
Move the On/Auto/Off
lever to "ON/AUTO"
posi-
tion. The compressor
will start.
5.
Run the compressor
for 15 minutes. Make sure
the drain valve is open and there is minimal air
pressure build-up in tank.
6.
After 15 minutes close the drain valve (clockwise).
The air receiver will fill to "cut-out"
pressure and
the motor will stop.
The compressor
is now ready for use.
Before
Each Start=Up:
1.
Place On/Auto/Off
lever to "OFF".
.
.
Pull regulator knob out, turn counter-clockwise
until it stops. Push knob in to lock in place.
Attach hose and accessories. NOTE: The hose or
accessory will require a quick connect plug if the
air outlet is equipped with a quick connect.
Too much air pressure
causes a hazardous risk of
bursting. Check the manufacturer's
maximum
pressure rating for air tools and accessories.
The regulator outlet pressure must never
exceed the maximum pressure rating.
How to Start:
1.
Turn the On/Auto/Off
lever to "AUTO" and allow
tank pressure to build. Motor will stop when tank
pressure reaches "cut-out"
pressure.
2.
Pull the regulator knob out and turn clockwise to
increase pressure. When the desired pressure is
reached push knob in to lock in place. The com-
pressor is ready for use.
NOTE: Always operate the air compressor
in well-
ventilated areas free of gasoline or other combustible
vapors. If the compressor
is being used to operate a
sprayer DO NOT place near the spray area.
11 - ENG
D23358