Descargar Imprimir esta página

GE PGP990 Serie Manual De Instrucciones página 27

Ocultar thumbs Ver también para PGP990 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

Installatidff°l tructions
INSTALLTHE COOKTOP
[] PREPARE THE COOKTOP
(cont.)
[]
9-pin
Remove the blank 9-pin connector plug from the
9-pin receptacle on the bottom of the cooktop
and discard. Connect the 9-pin plug on the blower
assembly to the matching 9-pin receptacle on the
bottom of the cooktop. Secure the connector cover
to the cooktop using 3 screws, making sure the
power cord comes out the U-shaped opening with
the wires to the motor.
.\....
__
CoNnector
cover
\\\\
jJ
\
INSTALL THE PRESSURE
REGULATOR AND CONNECT
Shut-off
valve
_
Regulator
_
olid piping or
flexible connector
(__
Union
__
Solid piping
or flexible connector
_r-__
Pipe stub
, For all connections, use a pipe sealant approved
by local codes and resistant to the activity of L.P.
gas.
, Install the pressure regulator in the gas line
as close to the cooktop inlet as possible to allow
clearance for ventilation ducting.
Make sure the arrow on the body of the
regulator is pointing straight up and toward the
cooktop. Any other position will affect the output
pressureofthe regulator.Thisarrowindicatescorrect
gas flow direction.
, Install a manual gas line shut-off valve in an
easily accessible location.
INSTALL THE PRESSURE
REGULATOR
AND CONNECT
(cont.)
NOTE: Instead of using solid piping to connect to
the pressure regulator,
an approved
flexible metal
appliance
connector
may be used between
the
shut-off
valve and the pressure regulator,if
local
codes permit.
Appropriate
flare nuts and adapters
are required
at each end of the flexible connector.
Make sure all the knobs are in the off position.
Hook up the gas line and check for leaks.
TEST FOR LEAKS
WARNING:
DO NOT USEA FLAME TO
CHECK FOR GAS LEAKS!DO notusethecooktopuntil
all connections have been leak tested.
Perform leek test per the following instructions:
2. Purchasea liquid leak detector or prepare a soap
solution of one part water, one part liquiddetergent.
2. When all connections have been made, make sure
all cooktop controls are turned to OFFand turn the
gas supply valve to ON.
3. Apply the liquid leak detector or the soap solution
around all connections from the shut-off valve to
the cooktop.
.
5.
A leak is identified by a flow of bubbles from the
area of the leak.
If a leak is detected, turn the gas supply off. Tighten
the fitting. Turn the gas on and test again.
If the leak persists,turn the gas supply off and
contact your dealer for assistance. Do not attempt
to operate the cooktop if a leak is present.
IMPORTANT: Disconnect the cooktop and the
individual shut-off valve from the gas supply
piping system during any pressure testing of that
system at test pressures greater than 1/2 psig.
Isolate the cooktop from the gas supply piping
system by closing the individual manual shut-off
valve to the cooktop during any pressure testing
of the gas supply piping system at test pressures
equal to or less than 1/2 psig.
27