13. INSTALL LIGHT BULBS
This hood must use 120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base, shielded halogen lamps (not included).
(2 required for 30" and 36" hood widths, 3 required for 42" and 48" hood widths).
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of
personal injury, only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a
lamp not suitable for use in recessed luminaires or identified for use in enclosed fixtures.
1. Install lamps by placing the bulb leads into their grooves in the socket.
2. Gently push upwards and turn clockwise until secure.
To remove lamps, gently push upwards and turn counterclockwise to disengage
bulb leads from their grooves.
NOTE:
If need be, use a rubber dishwashing glove to add grip when removing the
bulb.
14. REINSTALL GREASE DRIP RAIL AND FILTERS
HOO0080
Remove protective plastic film covering filters before installing them.
Reinstall grease drip rail. The illustration at right shows how to reinsert the
grease drip rail into the range hood.
NOTE:
Assemble the metal handles to the filters, using no. 8-32 x 1/4" screws
provided, before reinstalling them in the hood.
It is recommended to install side filters first and finish with center one(s).
1. Insert one end of the filter into the upper channel of the hood.
2.
Raise the other end toward the inside of hood and insert in the grease
drip rail of the hood.
-412-
HD0241
HD0242