Replace The Thermal Element; Replacing The Flow Rate Regulator - Franke AQLT0135 Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

22. Replace the thermal element

Warning!
Set the scald protection after installing the fitting or removing the thermal element.
Failure to observe this instruction can result in injuries due to scalding.
22.1 Close the water volume regulators (see
22.2 Trigger the fitting.
22.3 Remove the temperature selector (see
22.4 Remove the screw (b)
Caution!
Apply the pliers to the area with the largest diameter (a) behind the small sprocket
wheel.
If the sprocket wheel is damaged, the temperature selector cannot be installed.
22.5 Use pliers to remove the thermal element (c).
Important!
Note the installation position of the thermal element.
22.6 Reassemble in reverse order.
22.7 Set the scald protection (see

23. Replacing the flow rate regulator

23.1 Release the grub screw with an Allen key.
23.2 Pull the shower head out of the connection pipe.
23.3 Remove the locking ring on the inside using appropriate pliers for locking rings.
23.4 Pull out the flow rate regulator using flat-nosed pliers.
23.5 Replace the flow rate regulator. Observe the table.
Flow rate
0.15 l/s (orange)
0.20 l/s (red)
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
23.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
23.7 Slide the shower head onto the connection spigot.
23.8 Tighten the grub screw with an Allen key.
Work step
Chapter
Chapter
17.).
Flow rate regulator
FAR-Best.-Nr. 2000104782
FAR-Best.-Nr. 2000104783
- 12 -
12.16).
17.).

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aqlt0109Aqlt0111

Tabla de contenido