1134±2
Neigbare Halterung für Solarpanele (A5650)
Größe
U-förmiger Träger
217 × 45 × 1,5 mm (8,5 × 1,7 × 0,05 Zoll)
Vertikales Stützgerüst
1100 × 110 × 1,5 mm (43,3 × 4,3 × 0,05 Zoll)
Solarpanel-Tragarm
1200 × 108 × 1,5 mm (47,2 × 4,2 × 0,05 Zoll)
Unterer Tragarm
618 × 102 × 1,5 mm (24,3 × 4,0 × 0,05 Zoll)
Befestigungsklemme
130 × 48 × 1,5 mm (5,1 × 1,8 × 0,05 Zoll)
Endklemmen
92 × 40 × 2,0 mm (3,6 × 1,5 × 0,07 Zoll)
Haftungsausschluss
DIE HIER DARGELEGTEN EINGESCHRÄNKTEN GEWÄHRLEISTUNGEN ERSETZEN UND SCHLIESSEN ALLE ANDEREN
AUSDRÜCKLICHEN ODER STILLSCHWEIGENDEN GEWÄHRLEISTUNGEN AUS, EINSCHLIESSLICH, ABER NICHT BESCHRÄNKT
AUF GEWÄHRLEISTUNGEN DER MARKTFÄHIGKEIT UND EIGNUNG FÜR EINEN BESTIMMTEN ZWECK ODER EINE BESTIMMTE
ANWENDUNG, UND ALLE ANDEREN VERPFLICHTUNGEN SEITENS ANKER/SOLIX, SOFERN NICHT ANDERE GEWÄHRLEISTUNGEN
UND VERPFLICHTUNGEN SCHRIFTLICH MIT ANKER/SOLIX VEREINBART WERDEN. EINIGE GERICHTSBARKEITEN BESCHRÄNKEN
ODER GESTATTEN KEINE GARANTIEAUSSCHLÜSSE, SODASS DIESE BESTIMMUNG MÖGLICHERWEISE NICHT FÜR DEN KÄUFER
IN SOLCHEN GERICHTSBARKEITEN GÜLTIGKEIT ERHÄLT.
Garantie und Kundendienst
12 Jahre beschränkte Garantie für Anker RS40 Starres Solarpanel
15 Jahre beschränkte Garantie für Anker SOLIX RS40P Starres Solarpanel (445W)
12 Jahre beschränkte Garantie für Anker SOLIX MI80 Mikro-Wechselrichter (800W BLE)
2 Jahre beschränkte Garantie für Anker Verstellbare Solarpanel-Neigungshalterung
1 Jahr beschränkte Garantie für Anker Solarpanel-Verlängerungskabel (4.9ft, 4-Pack) und Anker MI auf Schuko-Anschlusskabel (16ft)
07 DE
A5507
9
R4.5
14
Label
Unit:mm
35
35
Nettogewicht
0,1 kg (0,2 lbs)
1,34 kg (2,9 lbs)
1,38 kg (3,0 lbs)
0,73 kg (1,6 lbs)
0,07 kg (0,15 lbs)
0,05 kg (0,11 lbs)
Important Safety Instructions
Lightning Surge Suppression
WARNING
To prevent the risk of electric shock caused by lightning strikes, make sure that the metal parts of the solar system are
connected to the ground.
The protective coating of the metal parts (such as the solar panel frame, brackets, the body of microinverter) is insulated:
• Scrape off the protective coating of the contact surface between the solar panel frame and the brackets.
• Scrape off the protective coating of the brackets and the microinverter's contact surface.
• Ensure that the brackets are connected to the microinverter through other conductors, such as metal railings.
• By following the steps above, the solar panel frame, brackets, and the body of the microinverter will be connected and
grounded via the ground wire and the microinterver's AC wire.
The solar system does not need to be struck by lightning to cause damage. A strike nearby often induces voltage spikes in the
electrical grid that can damage equipment. The microinverter has surge protection, but if the surge has sufficient energy, the
protection built into the microinverter can be exceeded—causing damage to the equipment.
Any solar installation should include surge protection since the warranty does not cover force majeure such as lightning strikes.
Surge protection devices should be installed according to the vendor's instructions.
Solar
Panel
WARNING
Before installing, wiring, operating, or maintaining the solar PV modules, you should read and understand all safety rules.
When the battery surface of the module is directly exposed to sunlight or other light sources, direct current (DC) will be generated.
Regardless of whether the module is connected or not, direct contact with the live parts of the module, such as the terminal, may
cause casualties.
Maximum series fuse rating 20A.
Power production tolerance +3%
This module produces electricity when exposed to light.
Follow all applicable safety precautions.
Only qualified personnel should install or perform maintenance work on the modules
Be aware of dangerous high DC voltage when connecting modules.
Do not damage or scratch the rear surface of the modules.
WARNING
Do not handle or install modules when they are wet.
Follow the battery manufacturer's recommendations if batteries are used with modules.
EN 08