Installation
1
Instalación
Installation
1. Select a location for mounting the Aromatherapy Module system in a utility area or closet near the steam room. The oil is injected directly into the
steam line with an Aroma Injection Tee (15) going to the steam head. The distance from each pump to the tee should not exceed SIX FEET. This
tee and the clear discharge tube (8) that carries the oil to the tee (15) must not be installed inside walls. This tubing and tee must be completely
accessible for proper setup. Do not install any part of this assembly in a wall. The location may be above or below the steam line connection. The
location should be convenient for replacing the oil canisters
2. Make sure a 120 volt outlet is located next to the Aromatherapy Module mounting location.
3. Secure two screws in the wall to hang the Aromatherapy Module in this location. The screws should be placed 5" apart and level.
4. Route the control cable from the Aromatherapy Module location to the 8GE-TSG series generator (or optional Chromatherapy, Audiotherapy
and SensoriPLus). The manners in which the cables are routed are dependent on what is best suited for the installation. Three are four connec-
tion jacks in 8GE-TSG series generator(s) and two in the Aromatherapy, Chromatherapy, Audiotherapy and SensoriPLus allowing for gangable
connections in the most convenient arrangement. The manner in which each product is interconnected is not important only that each product is
interconnected.
5. Choose a location for the tee . The location is preferable to be level with or above the steam head. DO NOT install the tee below the steam head.
This will provide a better aroma flow to the steam room and prevent backflow of oil to the generator. When the steam generator outlet is located
below the Steam head make a minimum of a 1" riser in the steam line located between the steam generator and the aroma injection tee. This will
prevent the aroma oil from backing up into the generator. The location of the tee must remain accessible after the installation is complete. The
injection tee is not intended to be buried in the wall. Make sure the plastic fittings are removed before sweating the tee in place. Sweat the tee
into the steam line in the horizontal position (shown in Figure 2). Do not install in any other position.
6. Plug the power cord (supplied) into the Aromatherapy Module's circuit board (shown in Figure 4) and to an outlet. Make sure the pump rollers (6)
spin when the switches are pressed on the Aromatherapy Module. If the pump does not spin check that the power supply is securely plugged
into the pump control circuit board located behind the pump panel.
Aromatherapy oils should not be ingested; even ingesting a small amount can cause poisoning. Aro-
matherapy oils should also not be applied to the skin and should be kept out of reach of children and
pets. Aromatherapy oils are not a cure for medical conditions and should not be used to treat medical
conditions. Elderly and pregnant individuals and those with a pre-existing medical condition should not
use this device without consulting a physician in advance. Do not use the steam bath while under the
influence of alcohol or drugs.
Figure 3 - Installation/Instalación
Control cable to
8CH-600, 8CB-600
or 8CN-600 Series
Controls
Cable de control a la
serie de controles
8CH-600, 8CB-600 o
Serie 8CN-600
Câble de commande
relié à l'appareil de
commande de la série
8CH-600, 8CB-600 ou
8CN-600
8GE-TSG
Series Generator
Aromatherapy
Module
Módulo de
aromaterapia
Module
d'aromathérapie
120V
Control cable
Cable de control
Câble de commande
Tubo de vapor
Tuyau de vapeur
WARNING
!
Aroma injection tubes
Max. length 6 feet (supplied)
Tubos de inyección de aroma
máx. longitud 6 pies (suministrado)
Tubes d'injection d'huile aromatique
Longueur maximale de 6 pi (fournis)
Steam pipe
Aroma injection tee
T con inyección de aroma
Raccord en T d'injection
d'huile aromatique
3
Steam head
Cabezal de vapor
Tête de vapeur
113382 Rev. B