Assembly and Setup
2
Montaje y configuración
Assemblage et montage
1. The black peristaltic tube (5) needs to be installed into the pumps (see Figure 6).
• Remove (unsnap) the blue plastic cover (1) exposing the pump roller assembly.
• Pull out the Rotor (3) about a ¼"
• Place the tube between the pump base (4) and each of the rollers (2) forming a loop where the tube (7) follows the inside upper curve of the
pump base.
• Push the lower right and lower left ends of the black tubing into the blue pump base securing it in the provided groves.
• Replace the blue cover on to the pump base. Verify that the pump cover is fully seated to the base, so there is no space and the pump
cover is not crushing the tube.
• Repeat the above procedure for the second pump.
2. Clear Tubing connections: The clear tubing that is used to carry the oil to the steam line is secured with special 1/8" tubing fittings (8). These
fittings are assembled by sliding the tube through the nut (6) and bottoming the tube into the fitting. Then tighten the nut until the tube is secured
(see Figure 7).
• With the bottles removed the clear suction tubes (7) should extend from the left side of the pump to the bottom of the cabinet. This will
ensure that when the bottles are in place the tube extends to the bottom of the bottle. Connect the clear tube to the black peristaltic tube on
the left (inlet) side of each pump.
• Connect the outlet side of each pump (right side) to a length of clear tube (7) that will be long enough to reach the tee connected to the
steam line.
• Route the tube through the hole in the front pump panel and out the hole in the right side of the cabinet to the tee.
• Connect the tube for each pump to the fittings on the tee adapter. (See Figure 2).
Figure 6
3
1
Figure 4
5
4
8
2
Power cord
Power
Cable de alimentación
Cord
Cordon d'alimentation
Figure 7
8
6
7
5
113382 Rev. B