Descargar Imprimir esta página

Baeza COSMOS 134234 Manual De Usuario página 34

Sistema de ósmosis inversa

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
WATER LEAKS
SCANT
PRODUCTION
When the tap is
opened, the
supply
immediately
ceases, leaving a
slight continuous
drip.
SCANT
PRODUCTION
The equipment is
continuously
rejecting water in
the drain.
THE EQUIPMENT
DOESN'T
PRODUCE
WATER FLAVOUR
CHANGES
WRONG WATER
ASPECT
Av. de Velázquez s/n
(Cruce Aeropuerto) 29004 Málaga
POSITION
Filter housing
Connection fitting
tubes;
Part of the thread:
Connection
fitting
tubes;
Part of the tube:
Dispensing tap:
The collector tank is
full:
The collector tank is
empty:
The collector tank does
not fill up:
The collector tank is
overflowing:
The collector tank is
empty:
The collector tank is
empty:
The water has a milky
appearance on the
surface
SOLUTION
The o-ring is dirty, misplace or pinched.
Teflon missing.
Badly installed bicono.
Badly threaded tube fittings.
Badly cut or pinched tube.
Regular handle height.
Remove the nozzle and the button.
In case of wear of the tap replace it.
Lack of air in the collector tank. Restock
(between 0.3 kg and 0.5 kg).
The tank tap is closed.
Punctured collector tank membrane.
Water comes out of the air inlet valve.
Change collector tank.
You must wait between 3 and 5 hours for
the collector tank to be full.
The collector tank inlet valve is closed.
Excessive amount of air in the collector
tank. Check the pressure (between 0.3 kg
and 0.5 kg).
Dirty filters. Replace.
The inlet pressure is less than 3 kg/cm2.
Install a pump.
Membrane in poor condition. Replace.
The flushing valve is open.
SHUTT OFF valve is dirty, has a torn
membrane or does not work. Replace.
The non return elbow located in the
membrane container does not work.
Replace.
Possible water leakage.
Clogged filters.
Clogged, broken or closed inlet tap of the
equipment.
Blocked membrane.
Change of mineralization in water due
to saturation or clogging of filters or
membrane (replace the membrane).
Accumulated airbags in the general
network of the accumulation or in the
osmosis equipment.
www.baezaonline.com