CONSUMER: READ AND SAVE THESE INSTRUCTIONS
DANGER
Be sure to comply with the instructions and warnings provided with this heater. Failure to
comply can result in fire or explosion that can cause property loss, bodily injury, or loss
of life. Only persons who can follow and understand these instructions should operate or
service this heater. If you need heater info; such as an operating manual, labels, etcetera,
contact Pinnacle Climate Technologies at 866-676-1989.
DANGER
FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS
OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. This is an
unvented portable heater that uses air (Oxygen) from within the area in which it is used.
Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon
monoxide poisoning, bodily injury or death. Refer to "Ventilation" on Page 5.
WARNING
instructions. Never use the heater in spaces which contain products such as; gasoline,
solvents, paint thinners, dust particles, volatile or airborne combustibles or any unknown
chemicals. This is an unvented portable heater. It uses air (Oxygen) from the area in which
it is used. Adequate combustion and ventilation air must be provided. Refer to "Ventilation"
on page 5. Bulk fuel storage should be a minimum of 25 feet from heater.
WARNING
OPERATING INSTRUCTIONS.
Failure to comply with the precautions and instructions provided with this
heater can result in death, serious bodily injury, property loss or damage
from the hazards of fire, soot production, explosions, burns, asphyxiation or
carbon monoxide poisoning. Only persons who can read and understand
these instructions should use or service this heater
FACTORY ID: 001
Model Numbers
REM-215T-KFA-O
Safety Information
GENERAL HAZARD WARNING: READ AND UNDERSTAND
ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE
ASSEMBLING, STARTING, OR SERVICING THE HEATER.
NOT FOR USE IN RESIDENTIAL LIVING AREAS OR IN
ENCLOSED SPACES WITHOUT ADEQUATE VENTILATION.
FOR OUTDOOR USE. INDOOR USE PERMITTED ONLY
FIRE, BURN, INHALATION AND EXPLOSION HAZARD. Keep
combustibles such as; building materials, paper or cardboard a
safe distance away from the heater as recommended by these
DO NOT OPERATE THIS HEATER UNTIL
YOU HAVE READ AND THOROUGHLY
UNDERSTAND THESE SAFETY AND
Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com
KEROSENE FORCED AIR
User's Manual &
Operating Instructions
.
1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989
© 2017 Pinnacle Climate Technologies, Inc. RGKD-403
HEATER

Publicidad

loading

Resumen de contenidos para Remington REM-75T-KFA-O

  • Página 1 KEROSENE FORCED AIR HEATER User’s Manual & Operating Instructions Model Numbers REM-45-KFA-O / REM-75T-KFA-O / REM-135T-KFA-O / REM-175T-KFA-O / REM-190T-KFA-O REM-215T-KFA-O CONSUMER: READ AND SAVE THESE INSTRUCTIONS Safety Information GENERAL HAZARD WARNING: READ AND UNDERSTAND DANGER ALL OF THE INSTRUCTIONS IN THIS MANUAL BEFORE ASSEMBLING, STARTING, OR SERVICING THE HEATER.
  • Página 2 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE WARNING DO NOT START THE HEATER WHEN EXCESS OIL HAS ACCUMULATED. WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT. CALIFORNIA RESIDENTS: This product contains chemicals, WARNING including lead, known to the State of California to cause birth defects or other reproductive harm.
  • Página 3 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Safety Information NEVER move or handle heater while still hot. RISK OF WARNING ELECTRIC NEVER transport heater with fuel in tank. SHOCK! NEVER use with an external fuel tank. ALWAYS use only the electrical power (voltage and Keep all combustible materials away from this heater.
  • Página 4 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Wiring Diagrams 45-KFA 75T - 215T-KFA Assembly Instructions Note: Save the box and packaging materials - Remove the heater and all packaging materials from the shipping carton for future storage.
  • Página 5 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE What’s In The Box Models: 135T-KFA / 175T-KFA / 190T-KFA / 215T-KFA Tools Needed: Tip: Be sure to remove the axle from the side of - Phillips Head Screw Driver the Styrofoam packaging.
  • Página 6 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation Fueling The Heater: Ventilation: Kerosene (K-1) - Risk of indoor air pollution and Carbon Monoxide For optimal performance of this heater, it is strongly Poisoning. Use heater only in well ventilated areas. suggested that K-1 kerosene be used.
  • Página 7 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Operation Starting the Heater: (Ignition) Stopping / Restarting Heater: - To stop the heater, move the power switch to the “Off” 1. Fill the tank with kerosene or other approved fuel position and unplug the power cord.
  • Página 8 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Service: ROTOR: DO NOT TAMPER WITH THE UNIT. HAVE The rotor with carbon vanes should be evaluated A COMPETENT SERVICEMAN MAKE ANY every heating season. The rotor is behind the air NECESSARY ADJUSTMENT OR REPAIRS.
  • Página 9 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Maintenance Service (Continued): PUMP PRESSURE: While heater is operating, turn adjusting screw SPARK PLUG: clockwise to increase, counter-clockwise to Clean and re-gap every 600 hours of operation, or decrease pressure.
  • Página 10 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Troubleshooting Guide Problem Possible Cause Solution Heater Ignites, but main PCB shuts 1. Incorrect pump pressure. 1. Adjust pump pressure. off after a short period of time. 2.
  • Página 11 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 34** 35** 41** 38** 37** * 45-KFA - 75T-KFA Only ** 135T-KFA - 215T-KFA Only 39** © 2017, Pinnacle Climate Technologies, Inc. Kerosene Forced Air Heater User’s Manual...
  • Página 12 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Parts List Description 45-KFA 75T-KFA 135T-KFA 175T/190T-KFA 215T-KFA Drain Plug – – 70-002-0105 70-002-0105 70-002-0105 Fuel Gauge 70-007-0110 70-007-0115 70-007-0210 70-007-0210 70-007-0215 Fuel Filter 70-003-0100 70-003-0100 70-003-0200 70-003-0200 70-003-0200 Fuel Cap - Large Plastic...
  • Página 13 NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE LIMITED WARRANTY Pinnacle Climate Technologies, Inc. warrants this heater If Pinnacle Climate Technologies, Inc. finds the item to to the original retail purchaser only, to be free from defects be in normal operating condition, or not defective the item in material and workmanship for a period of one (1) year will be returned freight collect.
  • Página 14 1 Industrial Blvd #101, Sauk Rapids, MN 56379 USA • Toll Free (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Email: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc.
  • Página 15 CALENTADOR DE AIRE FORZADO DE QUEROSENO Manual del usuario e Instrucciones de operación Modelos N.° REM-45-KFA-O / REM-75T-KFA-O / REM-135T-KFA-O / REM-175T-KFA-O / REM-190T-KFA-O REM-215T-KFA-O CONSUMIDOR: LEA Y CONSERVE ESTAS INSTRUCCIONES Información de seguridad ADVERTENCIA GENERAL DE PELIGRO: LEA Y COMPRENDA...
  • Página 16 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN NO ENCIENDA EL CALENTADOR CUANDO SE HAYA ACUMULADO UN EXCESO DE ACEITE. NO ENCIENDA EL CALENTADOR CUANDO LA CÁMARA ESTÁ CALIENTE. RESIDENTES DE CALIFORNIA: Este producto contiene sustancias químicas, incluyendo plomo, conocidas en el estado de California como causantes de defectos de nacimiento u otros daños reproductivos.
  • Página 17 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Información de seguridad NUNCA use conductos en la parte frontal o ¡RIESGO DE posterior del calentador. DESCARGA ELÉCTRICA! NUNCA mueva ni manipule el calentador SIEMPRE utilice la energía eléctrica (voltaje y mientras esté...
  • Página 18 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Diagramas eléctricos 45-KFA PCI DE CONTROL NEGRO ROJO BUJÍA ENCEN- DEDOR ROJO NEGRO LUZ (LED) NARANJA NEGRO VENTILADOR 1 MOTOR DE LA BLANCO ROSA VENTILADOR 2 BOMBA...
  • Página 19 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Qué hay en la caja Modelos: 135T-KFA / 175T-KFA / 190T-KFA / 215T-KFA Herramientas necesarias: Consejo: Asegúrese de retirar el eje del lateral - Destornillador Phillips del empaque de espuma de poliestireno.
  • Página 20 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Funcionamiento Llenar combustible en el calentador: NOTA: El queroseno debe almacenarse únicamente en un contenedor azul que esté claramente identificado con la Queroseno (K-1) palabra “queroseno”.
  • Página 21 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Funcionamiento Encendido del calentador: (Ignición) - Cuando la temperatura es superior a 99 ºF (37.2 ºC) la pantalla mostrará “HI”. 1. Llene el tanque de queroseno u otro combustible - Entre 0 °F (-18 ºC) y 99 °F (37.2 ºC) el indicador aprobado hasta que el indicador de mostrará...
  • Página 22 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Servicio: el extremo de plástico colocado debajo del soporte NO ALTERE LA UNIDAD. PIDA A UN TÉCNICO del motor/motor y alejado del aspa del ventilador. COMPETENTE QUE HAGA LAS REPARACIONES ROTOR: O AJUSTES NECESARIOS.
  • Página 23 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Mantenimiento Servicio (Continuación): PRESIÓN DE LA BOMBA: Mientras el calentador está funcionando, gire BUJÍA: la válvula de seguridad hacia la derecha para Límpiela y reajuste la separación entre los electrodos aumentar la presión o hacia la izquierda para de la bujía después de cada 600 horas de disminuirla.
  • Página 24 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Guía para la solución de problemas Problema Posible causa Solución El calentador se enciende, 1. Presión de la bomba incorrecta. 1. Ajuste la presión de la bomba. pero la placa de circuitos 2.
  • Página 25 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Vista detallada 34** 35** 41** 38** 37** * Sólo 45-KFA - 75T-KFA ** Sólo 135T-KFA - 215T-KFA 39** © 2017, Pinnacle Climate Technologies, Inc. Manual del usuario del calentador de aire forzado de queroseno...
  • Página 26 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN Lista de piezas Descripción 45-KFA 75T-KFA 135T-KFA 175T/190T-KFA 215T-KFA Tapón de drenaje – – 70-002-0105 70-002-0105 70-002-0105 Indicador de combustible 70-007-0110 70-007-0115 70-007-0210 70-007-0210 70-007-0215 Filtro de combustible...
  • Página 27 NUNCA DEJE DESATENDIDO EL CALENTADOR MIENTRAS ESTÉ ENCENDIDO O MIENTRAS ESTÉ CONECTADO A UNA FUENTE DE ALIMENTACIÓN GARANTÍA LIMITADA Pinnacle Climate Technologies, Inc. garantiza este Si Pinnacle Climate Technologies, Inc. descubre que el calentador únicamente al comprador minorista original, artículo está en condiciones normales de funcionamiento como libre de defectos en materiales y mano de obra por o que no está...
  • Página 28 1 Industrial Blvd #101, Sauk Rapids, MN 56379, EE. UU. • Llamada sin costo: (866) 676-1989 Fax: 320-251-2922 • Web: www.remingtonheater.com • Correo electrónico: info@pinnacleclimate.com © 2017 Pinnacle Climate Technologies, Inc.