10.3 Correcting vertical mitre angles
Should the actual value no longer correspond to
the angle you set, this can be corrected:
► Lock the saw unit in the 0° position.
► Loosen the two screws [23.1].
► Swivel the saw unit until it matches the ac
tual 0° value. You can check this against an
angle between the saw table and the saw
blade.
► Retighten the two screws [23.1].
► Check the angle adjustment by making a
sample cut.
23.1
23.1
23a
Should the indicator [23.3] no longer point to
the set value, you can adjust it after loosening
the screw [23.2].
22.1
22.2
23b
10.4 Replacing the table top insert
Do not work with a worn-out table top in
sert [24.1]; replace it with a new one instead.
► Unscrew the six screws [24.2] to replace
the table top insert.
24.2
24
10.5 Cleaning/replacing the window for the
laser
The window [25.2] which protects the laser can
become dirty during operation. You can remove
the window to clean or replace it.
► Loosen the screw [25.5] by approx. two ro
tations.
► At the same time, push the window in direc
tions [25.3] and [25.4].
► Remove the window.
► Clean the window or replace it with a new
one.
► Insert the cleaned/new window. The two
pins [25.1] of the window must engage in