Installation
Figure 5
5. Power Supply: This pump requires a 115 V.,
60 Hz., 15 amp individual branch circuit.
The circuit must be grounded and should
be dedicated to the sump pump. The pump
is supplied with a 3-wire cord set with
grounding-type plug. Plug the switch directly
into the outlet and plug the pump into the
opposite end of the switch's plug.
Risk of electric shock. Can
shock, burn or kill. Always ground the pump
to a suitable electrical ground, such as a
grounded water pipe, a properly grounded
metallic raceway, or a ground wire system. Do
not cut off the round ground pin.
For parts or assistance, call Flotec Customer Service at 1-800-365-6832
Figure 6
6205 0410
6. After you have installed the piping, check
valve, and float switch, the pump is ready for
operation.
Check the pump by filling the sump with water
and observing the pump's operation through
one complete cycle. For switch settings see
Electrical and Switch Specifications.
this operational check may lead to improper
operation, premature failure, and flooding.
6206 0410
Risk of flooding. Failure to make
4