Descargar Imprimir esta página

Setting The Clock - Zibro SRE 440 E Instrucciones De Uso

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54
B
C
D
E
empty
full
F: When the 4-digit stops
blinking, the setting
has been locked to the
indicated value.
4
78
5 Insert the plug ¸ into the wall-socket (230 Volts - AC / 50 Hz) and set the
correct time using the adjustment keys
6
Your Zibro is now ready for use.
B
FILLING FUEL
Fill the removable tank in a suitable place since there can always be some spillage.
Follow the procedure below:
1
Make sure that the heater is switched off.
2
Open the upper lid and lift the removable tank out of the heater (Fig. B).
Note: Some drops may leak from the tank. Put down the removable tank (cap
pointing upwards, handle on floor (Fig. C) and screw off the fuel cap.
3
Fill the removable tank using a fuel pump (refer to fuel pump operation
instructions.) Make sure that it is in a higher position than the removable tank
(Fig. D). Insert the ribbed hose into the opening of the removable tank.
4
Check the removable tank fuel gauge while filling the tank (Fig. E). Stop
filling once the gauge indicates that the tank is full. Never overfill the tank,
especially not when the fuel is very cold (fuel expands when it heats up).
5
Check whether the fuel cap is straight and tightened properly. Reinstall the
removable tank in the heater (cap down). Close the lid.
C

SETTING THE CLOCK

It is only possible to set the correct time and day, when the heater is connected to
the mains and not burning. Use the adjustment keys
(weektimer)
to set the day.
First press one of the three keys to switch on the function (the 4-digit ¹ will start
blinking). Next, set the hours using the key (
key (
min.) and the day using the key extension day/set
Press once to increase the value by one step. When you hold down the key, the
value will continue going up, until you release the key again. After approximately
10 seconds the 4-digit will stop blinking and the setting will be locked. 5 minutes
after switching off the heater, the information on the display will disappear and
the heater will automatically switch into the stand-by position.
When the heater has been unplugged for more than 30 minutes (or after a
power failure), the time and the day need to be set again.
(refer to Section C).
to set the time and day/set
hour) and the minutes using the
.

Publicidad

loading