7. TECHNICAL SPECIFICATIONS

7.1.

TECHNICAL CHARACTERISTICS

Accuracy is indicated as
AC/DC Voltage
Range
Resolution
6, 12, 24, 50,
120, 230, 400,
690V
Max output current:
Detection AC/DC voltage:
Measuring range selection:
Frequency range:
Minimum detected voltage:
AC Voltage with low input impedance
Range
12  230V
Max output current:
Detection AC voltage:
Measuring range selection:
Frequency range:
Minimum detected voltage:
1-wire AC voltage detection (polarity)
Voltage range:
Frequency range:
Continuity test
Range
Phase sequence indication
Voltage range:
Frequency range:
Measurement method:

7.1.1. Reference guidelines

Safety:
EMC :
Insulation:
Pollution degree:
Measurement category:
Max height of use:

7.1.2. General specifications

Mechanical characteristics
Dimensions (L x W x H):
Weight (including batteries):
Mechanical protection:
[%reading + (dgt * resolution)] at 23°C±5°C, <70%RH
Accuracy
(1.0rdg+3dgt)
(DC Voltage)
1V
(1.5rdg+5dgt)
(AC Voltage)
<1mA (400VAC); <1.5mA (690VDC)
automatic
automatic
50/60Hz
4.5V (AC), 3V(DC)
Resolution
Measuring time
1V
max 5s < 250V
Is ≤ 200mA @690V, max 30s (ca. 48mA @ 230V)
automatic from 12V
automatic
50/60Hz
12VAC
100V  690VAC
50/60Hz
Buzzer
Test current
<200kΩ
180V  440VAC
50/60Hz
2-wire with contact to live parts
Input impedance
Input impedance
<1A
IEC/EN61010-1, IEC/EN61243-3 :2014
IEC/EN61326-1
double insulation
2
CAT III 1000V, CAT IV 600V
2000m (6561ft)
240 x 78 x 40mm (9.4 x 3.1 x 1.6in)
240g (7.7ounces)
IP64
EN - 13
Overload protection
690VAC/DC
1M
Overload protection
3s <400VAC,
< 6k
690VDC
Overload protection
690VDC/400VAC
HT7