ADJUSTMENT COMPARTMENT
Loosen the four screws in the metal lid of the adjustment compartment using the 2 mm hex tool provided and remove the lid. Use the hex
tool attached inside the adjustment compartment (1.5 mm) to adjust the laser beams R, G and B. For details of how to adjust the laser
beams, see under LASER BEAM ADJUSTMENT in these instructions.
7
VENTILATION SLIT
Take care to ensure that the ventilation slits at the front and back are not covered and that air can circulate freely. Check the four internal
fans regularly to ensure they are working correctly (visual check from the back) and have the device serviced by an authorised service
centre at regular intervals.
8
RUBBER FEET
On the bottom of the device are four rubber feet for non-slip set-up on a suitable surface.
16
9
POWER IN
Neutrik powerCON mains input socket Operating voltage 100–240 V AC/50–60 Hz. Use the power cable provided.
10
FUSE HOLDER
Fuse holder for a 5 x 20 mm fine-wire fuse. Replace the fuse only with a fuse of the same type and of the same value according to the
stamp on the device! In the event of repeated fuse failure, please contact an authorised service centre.
11
POWER
On/off switch for power supply to the device.
12
POWER OUT
Neutrik powerCON mains output socket for power supply to other CAMEO LIGHT products. Ensure that the total current consumption of all
connected devices does not exceed the value specified on the device in amperes (A).
13
KEY SWITCH ON/OFF
Lock switch for switching the integrated laser on and off. The laser is deactivated in the OFF position and activated in the ON position. Two
keys are included. In order to ensure the device cannot be operated by unauthorised persons, lock the switch and remove the
key!
14
INTERLOCK
The interlock connection allows an emergency stop system to be set up so as to be able to switch off any connected effect
lasers directly by remote control in the event of a hazard. Cameo D. FORCE lasers can only be operated if the interlock circuit
is closed: when the emergency off switch is activated, a contact is opened, breaking the circuit.
INPUT: Male 3-pin XLR socket to connect the optionally available CAMEO emergency off switch with an XLR socket; use a commonly
available microphone or DMX cable for this purpose. If the emergency off switch is not used, the bridging plug supplied has to be plugged
into the interlock socket in order to be able to activate the laser. The bridging plug is for service purposes only and may not be used
at events with an audience!
OUTPUT: Female 3-pin XLR socket to connect compatible laser products to the interlock emergency off system.
15
SFS ON/OFF
The Scan Fail Safety system prevents emission of a dangerous spot beam and should therefore be switched on at all times. Only deactivate
the Scan Fail Safety system in exceptional cases (e.g. when adjusting the laser) and only if absolute care has been taken to ensure that
persons, animals and combustible materials will not be hit by laser beams (also take care of mirrors and other reflecting materials)!
16
ILDA IN
ILDA input with 25-pin D-sub connector for computer control. ILDA software for show programming is not
included.