BURNER AND NOZZLE SPECIFICATIONS
Type of gas used
Type of burner
Rapid (R)
NATURAL GAS
Semi-rapid (SR)
G20
(Methane)
Auxiliary (AUX)
2 Ring (DC)
Rapid (R)
LIQUEFIED
Semi-rapid (SR)
PETROLEUM GAS
Auxiliary (AUX)
G30
(Butane)
2 Ring (DC)
Rapid (R)
LIQUEFIED
Semi-rapid (SR)
PETROLEUM GAS
Auxiliary (AUX)
G31
(Propane)
2 Ring (DC)
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz - 0,6W
Injector
marking
128 B
97
78 A
136 A
87
67
50
95 A
87
67
50
95 A
Model con guration
Rated thermal owrate
5 BURNERS
1R - 2SR - 1AUX - 1DC
1R - 2SR - 1AUX - 1DC
1R - 2SR - 1AUX - 1DC
Rated thermal
Rated
ow rate
consumption
kW
3,00
286 l/h
1,65
157 l/h
1,00
95 l/h
3,80
362 l/h
3,00
218 g/h
1,65
120 g/h
1,00
73 g/h
3,80
276 g/h
3,00
214 g/h
1,65
118 g/h
1,00
71 g/h
3,80
271 g/h
Total rated consumption Air required (m
(kW)
11,10
11,10
11,10
CATEGORY II2H3+
Reduced heat
capacity
kW
min.
0,60
0,35
17
0,30
2,20
0,60
0,35
20
0,30
1,90
0,60
0,35
25
0,30
1,90
1m
1057 l/h
807 g/h
793 g/h
Gas pressure
mbar
rat.
max.
20
25
28-30
35
37
45
) for burning
3
of gas
3
9,52
30,94
23,80