EN
Specifications
8
Product Name
Model
L × W × H*
Net Weight*
Inverter Model
Included Battery Pack Model
Rated Frequency
Max. Power of Output in Total
Power
AC Max. Output Power
Station
DC Max. Output Power
AC Input
Car Input
Solar Panel Input
AC Output (× 3)
Car Outlet
DC5525 Output (× 2)
USB Type-A Output (× 4)
USB Type-C Output (× 2)
Discharge Temperature
Charge Temperature
Model
L × W × H*
Net Weight*
Battery Type
Nominal Capacity
Battery
Pack
Nominal Energy
Nominal Voltage
Max. Charging Voltage
IP Rating
Battery Management System
* It may slightly differr from the actual value due to different measuring tools and methods.
19
Segway Portable Power Station Cube
CUBE-1000
CUBE-2000
13.9 × 11.3 × 11.1 in
13.9 × 11.3 × 15.7 in
(354 × 289 x 284 mm)
(354 × 289 x 399 mm)
35.7 lbs (16.2 kg)
57.5 lbs (26.1 kg)
CUBE-IV-2200
CUBE-BT-1000
CUBE-BT-1000,CUBE-BTX-1000
60 Hz
2200 W
2584 W
2200 W
384 W
120 V~8 A 60 Hz 1250 W Max
12 V/24 V 8 A 200 W Max
12-60 V 800 W Max
120 V~20 A 60 Hz 2200 W Max (inverter mode, pure sine wave) /
120 V~ 60 Hz 12 A Max. (bypass mode)
13.6 V 10 A 136 W Max
13.6 V 5 A 68 W Max
5/9/12 V 3 A 18 W Max
5/9/12/15/20 V 5 A 100 W Max
14°F~113°F (-10°C~45°C)
41°F~113°F (5°C~45°C)
CUBE-BT-1000
CUBE-BTX-1000
13.9 × 11.3 × 5.9 in
13.7 × 11.3 × 5.3 in
(354 × 289 x 152 mm)
(348 × 289 x 135 mm)
22 lbs (10 kg)
21.8 lbs (9.9 kg)
LFP (LiFePO
) Battery
4
20 Ah
1024 Wh
51.2 V
57.6 V
IP56
Protection against over temperature, over current, over voltage.
Troubleshooting
9
Error code
Possible causes
E01
Battery over temperature protection
E02
Battery low temperature protection
E03
Battery undervoltage protection
Battery communication error 1
E04
Battery communication error 2
E05
Over temperature protection during
E06
charging
Over temperature protection during
E07
discharging
Solar charging abnormality
E08
E09
AC Input error
E10
Car output overload or short-circuit
E11
USB output overload or short-circuit
E12
AC output overload protection
E13
AC output short-circuit protection
E14
Inverter malfunction
E15
Battery malfunction
E16
Internal wires malfunction
* For the error code from E09 to E16, if the error code still exists after operating with the above methods, please contact
the after-sales service for support.
Solution
Please cool down the battery
Please make the battery back to the normal temperature.
Please charge immediately!
1. Turn off the power station and check if the battery pack is
connected properly.
2. Restart the power station.
Note: if the error code still exists after operating with the above
methods, the battery pack might have been damaged.
1. Please cool down the power station.
2. Check the fan and cooling vents, and apply heat
dissipation for the power station.
1. Check the solar panel type (80V/20A). If matched, the
hardware circuit of the solar panel might have been
damaged, please contact the after-sales service for support.
2. If not, please disconnect the solar panel.
AC Input abnormality caused by unstable power grid,
please disconnect the AC charging cable.
Disconnect the loads. Turn off the DC output after 5
seconds and try again later.
Disconnect the USB devices.
Disconnect the loads. Turn off the AC output after 5 seconds
and try again later.
Disconnect the AC devices. Turn off the AC output after 5
seconds and try again later.
Keep the power station stand still and restart it.
Disconnect all the input/output devices and restart the
power station.
EN
20