Descargar Imprimir esta página

Magmaweld monoCUT 45ix Manual Del Usuario página 29

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 197
monoCUT 45ix / monoCUT 45i
E14
System Error
Error Code
Error
Remote Control
E15
Communication
E16
E17
System Error
E18
Thermal
E19
Protection
(Secondary)
E20
E21
System Error
E22
E23
Inlet Pressure
E26
Torch Shield Not
E27
Installed
E28
System Error
DC Busbar
E29
Voltage Low
DC Busbar
E30
Voltage High
E31
System Error
www.magmaweld.com
• There may be a hardware error
• There may be an error in the remote
control connections
Error
• There may be a hardware error
• The uptime of your machine may have
been exceeded
• Fan may not be working
• The front of the air inlet - outlet ducts
may be blocked
• The machine working environment
may be too hot or stuffy
• There may be a hardware error
• Inlet pressure may be low
Low
• Torch shield may not be installed or
properly fitted
• There may be a hardware error
• Mains voltage may have decreased
• Mains voltage may have increased
• There may be a hardware error
• Contact the authorized service
Cause
• Check remote control connections
• If the problem continues, contact the
• Contact the authorized service
• Allow the machine to cool down by
• If the problem continues, contact the
• Visually check if the fan is working
• If the problem continues, contact the
• Unblock the front of the air ducts
• If the problem continues, contact the
• Make sure that the working
• If the problem continues, contact the
• Contact the authorized service
• Check your air / gas connections,
• Make sure that the torch shield is
correctly fitted to the machine
• If the problem continues, contact the
• Contact the authorized service
• Check the mains connection cables
• Check the mains connection cables
• Contact the authorized service
Maintenance and Service
Solution
authorized service
waiting for a while. If the fault
disappears, try to use the machine at
lower amperage values
authorized service
authorized service
authorized service
environment of the machine is not
excessively hot or stuffy
authorized service
make sure that the inlet pressure
is appropriate. If the inlet pressure is
normal, contact the authorized
service
authorized service
and the voltage. Make sure the
correct voltage input is providevd.
If the mains voltage is normal,
contact the authorized service
and the voltage. Make sure the
correct voltage input is provided.
If the mains voltage is normal,
contact the authorized service
USER MANUAL