The installation location must be dry and free from dust.
1.4
Special safety instructions and warnings for devices that use R290 refrigerant
(propane)
WARNING!
According to DIN EN 378-1 the R290 refrigerant belongs to
safety group A3.
The device is permanently sealed from a technical point of
view.
The filling quantity of the refrigerant is less than 150g.
Leave the device open for 5 minutes before commissioning.
Leaks can cause the highly-flammable refrigerant to form an
explosive gas/air mixture. This might result in a fire and ex-
plosions with a subsequent fire risk.
Therefore ignition sources (heat, sparks, open flames) should
be kept well away.
Minimum clearances between the device and more easily in-
flammable objects should be 2 m on all sides.
Do not use any items for defrosting other than those ap-
proved by the manufacturer.
Never use devices without explosion protection signs for
cleaning in the cooling and machine rooms.
Maintenance is only to be carried out without power, i.e. after
the power has been disconnected from the device.
You must ensure that the device is disposed of correctly.
Work that involves opening the refrigerant circuit must only
be carried out by qualified persons (specialists) and only with
good ventilation present.
Do not damage the refrigeration circuit!