Install a double - pole switch, protected fuses of the delayed
type, upstream the electricity wall socket 10A.
Make sure that circuit breakers, fuses, etc. are of sufficient
capacity to handle start - up current (normally for no longer
than a second).
All wiring must conform to the local electrical codes. Consult
your dealer or a qualified electrician for details.
SAFETY INSTRUCTIONS
EG
Read this booklet carefully before using this air conditioner.
If you still have any difficulties or problems, consult your
dealer for help.
This air conditioner is designed to give you comfortable
room conditions. Use this only for its intended purpose as
described in this Instruction Manual.
WARNING
Never use or store gasoline or other flammable vapor or liquid
near the air conditioner. It is very dangerous.
Moreover, never install electrical equipment, which is not
protected with IPX1 protection (protection against vertical
water drop), under the unit.
The manufacturer assumes no responsabilities if the safety
regulations or local codes are not observed.
CAUTION
Never use the power main switch to start or stop the air
conditioner: always use the ON/OFF button on the remote
control unit or the selector switch on the unit.
Do not stick anything into the air outlet of the air conditioner.
This is dangerous because the fan is rotating at high speed.
Do not let children play with the air conditioner.
Do not cool the room too much if babies or invalids are
present.
USING THE REMOTE CONTROL UNIT
HOW TO INSTALL BATTERIES
Slide the lid of the remote control unit
following the indication and remove it.
Insert two AAA alkaline batteries of
1,5 V-DC.
Make sure the batteries point in the
direction marked in the battery
compartment.
The batteries last about six months.
Depending on how much you use the
remote control unit.
Remove the batteries if you do not use the remote control unit
for more than one month.
Press the ACL button using a thin object, for ex. the point of
a pencil or a pen, after batteries replacement.
(This operation allows you to reset correctly all the programs.
The remote control unit is to be set up again).
Replace the batteries when the remote control unit lamp fails
to light, or when the air conditioner does not receive the remote
control unit signals.
TEMPERATURE SENSOR SELECTOR (A/C SENSOR)
Under normal conditions the room temperature is detected and
checked by the temperature sensor placed in the remote control
unit.
This button activates the temperature sensor placed in the
indoor unit. Press this button using a
thin object, for ex. the point of a pencil
or a pen. The display will show the
mark. The air conditioner will be set
according to the intake air
temperature of the unit (mean
temperature of room air).
For normal use it is recommended the temperature sensor in
the remote control unit to be activated.
The remote control unit sends the
temperature signal to the air
conditioner regularly at three minute
intervals. If the signal from the remote
control unit stops for more than ten
minutes due to some troubles, the air
conditioner will switch to the
temperature sensor which is built into
the indoor unit and controls the room temperature. In these
cases, the temperature around the remote control unit may
differ from the temperature detected in the air conditioner
position.
REMOTE CONTROL UNIT LOCATION
THE SCREWS NECESSARY FOR THE TWO DIFFERENT
INSTALLATIONS ARE SUPPLIED WITH THE INDOOR UNIT.
The remote control unit may operate either from a non-fixed position
or from a wall-mounted position. To ensure that the air conditioner
operates correctly, DO NOT install the remote control unit in the
following places:
In direct sunlight.
Behind a curtain or other places where it is covered.
More than 8 m. away from the air conditioner.
In the path of the air conditioner airstream.
Where it may become extremely hot or cold.
Where it may be subject to electrical or magnetic noise.
Where there is an obstacle between the remote control unit and
the air conditioner (a check signal is sent from remote control
unit every 3 minutes).
ACL BUTTON
1. Non-fixed position (1)
• Momentarily place the remote control unit in the desired
• Verify that the remote control unit can operate from this
• Hang the remote control unit on the mounting screw tightened
2. Wall-mounted fixed position (2)
• See non-fixed position (1).
• Remove the batteries from the remote control unit and tighten
• Locate the pretrimmed hole in the battery compartment.
• Through the pretrimmed hole fix the remote control unit at
• Insert the two batteries, check that the remote control unit
OPERATION WITH THE REMOTE CONTROL UNIT
Check that circuit breaker on the power
panel is turned ON and the operation
selector of the indoor unit is in the ON
position.
HOW TO USE THE REMOTE CONTROL
NIGHT
OFF ON
MODE
SETBACK
CLOCK
UNIT
FLAP
HH
TIMER
When using the remote control unit, always
SELECT
FAN SPEED
MM
point the unit trasmitter head directly at the
ACL
A/C
SELECT
TIME SET
SENSOR
air conditioner receiver.
4
NOTE
WALL
(1)
mounting position.
position.
into the wall.
the screw into the wall, then hang the remote control unit.
the wall using the supplied screw.
operates correctly.
CAUTION
REMOTE CONTROL
UNIT DISPLAY
WALL
(2)
INDOOR UNIT
RECEIVER
TRANSMITTER HEAD
REMOTE CONTROL UNIT