AIR FILTER
The air filter behind the air intake grille should be checked and
cleaned at least once every two weeks.
HOW TO REMOVE THE FILTER
Hold the air filter by the tab at the top of the intake grille. And then
pull upwards.
Storage
If you are not going to use the air-conditioner for a long
period, clean the air filters, evacuate the condensate from
the indoor unit through the drain hose at the unit back side.
Do not disconnect the flexible tube, unless you are obliged
to do it: in that case protect the open halves of the couplings
with the plugs supplied as accessories, that must be
tightened with a spanner. Do not put heavy objects on the
top of the unit, and protect it with a cloth or a plastic bag.
CONDENSATE DRAIN PIPE
FILTER CLEANING
Use a vacuum cleaner to remove light dust. If there is sticky dust
on the filter, wash the filter in lukewarm, soapy water, rinse it
in clean water, and dry it.
TIPS FOR ENERGY SAVING
DO NOT:
Block the air intake and outlet of the unit.
If they are obstructed, the unit will not work well, and may be
damaged.
Let direct sunlight into the room. Use sunshades, blind or
curtain.
DO:
Always try to keep the air filter clean. A clogged filter will impair
the performance of the unit.
To prevent conditioned air from escaping, keep windows, doors
and any other openings closed.
TROUBLESHOOTING
WARNING
• The use of portable telephones near the air-conditioner may
cause disturbance to its normal operation and must be avoided.
In case abnormal operation is noticed, (OPR operation lamp
lights but outdoor unit will not run) to restore normal operation
turn-off electric supply for 60 seconds at least, by disconnecting
the main switch or the wall plug, then start again the air-
conditioner.
• The lighting-up of the
air conditioner for a short time, 1 - 2 minutes, are due to the
exceeding condensate drainage. Otherwise, the lighting-up of
the same lamp and the definitely stop of the air conditioner
indicate that the condensate pump is not working or that the
condensate drain pipe in the flexible connection pipe is
obstructed; in this case contact the AFTER SALE SERVICE.
In case of emergency the air conditioner can work by draining
the condensate from the back little pipe into a rather short
container, extract the little pipe and remove the cap.
• If your air conditioner does not work properly, first check the
following points before requesting service.
If it still does not work properly, contact your dealer or service
center.
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Line voltage is too low.
4. Operation button is OFF.
5. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service center.
3. Consult your electrician or dealer.
4. Press the button again.
5. Replace batteries.
Trouble: O.P.R. (operation) lamp flashes and the air conditioner
does not operate.
Possible cause:
1. Trouble in wiring system.
Remedy:
1. Contact service center.
Trouble: Compressor runs but soon stops.
Possible cause:
1. Obstruction in front of condenser coil.
Remedy:
1. Remove obstruction.
Trouble: Poor cooling or heating performance.
Possible cause:
1. Dirty or clogged air filter.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. Thermostat is set too high (for cooling) or too low (for heating).
6. Outdoor temperature is too low (heat pump version).
7. Defrosting system does not work (heat pump version).
Remedy:
1. Clean air filter to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the temperature lower (or higher).
6. Try to use a back-up heater (heat pump version).
7. Consult your dealer (heat pump version).
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. In heating or cooling operation, any plastic parts may expand
or shrink due to a sudden temperature change. In this event,
a clicking sound may occur.
Remedy:
1. This is normal, and the sound will soon disappear.