Descargar Imprimir esta página

Matikgate Flow Manual Del Usuario / Instalador página 39

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MOTOR ASSEMBLY AND INSTALLATION
BEFORE INSTALLING
Pillar
If dimension B is between 0-300mm, dimension A should not be less than 110mm.
If dimension B is between 300-380mm, dimension A should not be less than 150mm.
INSTALLATION OF THE FIXING PLATE AND SUPPORT
Fixing plate
Fixing plate
Use Ø8mm screws and Ø14mm bushings to mount the fixing plate to the column.
The fixing plate must be fixed at a distance of not less than 150mm from the ground.
Fix support A on the gate leaf (use Ø8mm screws or weld). Support A must be fixed at
a distance of 450mm from the front hinge (horizontal), and 19mm from the fixing plate
(vertical).
*A
450
Hinge
Support A
Support A
150
Mechanical stop
450
19
MATIKGATE AUTOMATION
EN
39