Lower limit switch
Lower limit switch
1. Unlock the motor and open the gate leaf to the desired position.
2. Adjust the upper limit switch on the reduction shaft until the microswitch is activated,
fix the limit switch with the screw.
3. Unlock the motor and close the gate leaf, leaving 100mm before the fully closed
position. Adjust the lower limit switch until the microswitch is activated (closing). Fix
the limit switch with the screw. After completing the installation, make all electrical
connections and motor adjustments, place the cover, securing it with 4 screws.
Emergency unlocking is used to unlock the motor in the event of a power cut.
To unlock the motor, turn the crank 90 degrees.
Attention: Only unlock the motor if the power is off.
ADJUSTMENT OF LIMITS
Upper limit switch
Upper limit switch
Microswitch
Microswitch
EMERGENCY UNLOCKING OF MOTOR
Released
Released
Release
Release
handle
handle
Locked
Locked