ELECTRICAL SUPPLY
The unit is fitted with a 2.8 metre input cable and operates from a 220-240V 50-60Hz electrical supply. The input cable is hardwired
for electrical safety. If it is necessary to extend it, this must be done by a competent electrician.
When installed in wet or damp areas the cord must be terminated by a connector suitable for the environment. Ensure that once
installed, the power lead is adequately secured.
INSTALLATION
The Chameleon Qualis IP is designed to be wall mounted. The unit has two keyholes in the back panel to easily mount the unit
onto the wall.
Figure 1 – Keyhole mounting locations
To reduce UV light exposure to skin and particularly the eyes, PestWest recommends that the unit is mounted 1.8m above the
floor (measured from the lower edge of the unit). Also avoid mounting the unit in close proximity (less than 1m) from an area
where people are working for extended periods.
To mount the unit onto the wall firstly open the front cover by lifting outwards from the bottom (Note: when the cover is opened
approximately 45° it will stay open on its own). Next, open the two board retainer tabs at the bottom of the unit by twisting
outwards.
Figure 2 – Board Retainer Tabs