ENGLISH
Switch off the machine before servicing. It must be noted that LED lamps are nothing like fluorescent
lamps, failure to disconnect the unit from power when removing or inserting a lamp is likely to
permanently damage the LEDs. This will result in the LED lamp being irreparably damaged.
CHANGING THE LED LAMPS
Switch off the machine before servicing. Open the front cover by lifting outwards from the bottom (Note: when the cover is
opened approximately 45°, it will stay open on its own) To remove the LED lamp, first lift the lamp out of the metal clip on the
righthand side of the unit by pulling it out towards you (See Figure 3 below).
Figure 3. Removing the lamp from metal support clip.
Next, carefully pull the lamp and lamp holder out of the black rubber grommet on the left-hand side of the unit, sliding it towards
the right. Holding the tube in one hand, and the clear rubber lamp holder sleeve in the other, firmly pull the lamp out of the sleeve.
(See Figure 4).
Figure 4. Removing the lamp from the lamp holder.
CAUTION – Quantum X LED lamps are powered by Direct Current (D.C.) at one end only, which is easily recognised by
the silver end cap and the printing on the left-hand side (LHS), see figure 5. The D.C. input pins (LHS) require fitting in
the correct polarity, positive (+) and negative (-). Please note that the correct polarity is marked with a + & – symbol on
the Quantum X LED lamp (LHS printing) and the corresponding LED lamp pins must be fitted to the corresponding + & –
symbols on the lamp holders & metalwork, located on the left side of the trap, next to the lamp holders, see figure 5.
6