Electrical safety and advice on additional electrical
protection
• C o m m e r c i a l k i t c h e n s a n d c a t e r i n g a r e a s a r e
environments in which electrical appliances can be
placed near liquids, or operate in humid conditions or
where the limitation of movement for installation and
assistance is evident.
• Installation and periodic inspection of the appliances
must only be carried out by a qualified, experienced and
competent electrician; in addition, the appliances must
be connected to an adequate power supply according
to the load, as reported on the label containing the
appliance data.
• The installation and electrical connections must meet the
necessary requirements, in accordance with the local
regulations on electrical wiring and with the guidelines
for electrical safety.
• The following is recommended:
• Ensure additional electrical protection with the use of a
differential switch (RCD).
• Make sure that fixed wiring appliances include a local
disconnect switch to which they can be connected
and that this is easily accessible for shutdown and
safe isolation. The disconnect switch must meet the
requirements specified in the IEC 60947 standard.
For Australia and New Zealand the disconnect switch and
connection cable must comply with AS / NZS 3000.
⚠