Extra instruction: Open window detection:
Time round
Min: s
00:00 - 01:00
01:00-11:00
Remarks
Time
Description
Min: s
0:00
Open window detection start up
1:00
Temperature detection start up
Temperature detection starting check point
6:00
Temperature detection check point 1 (temperature
fast down detection check point).
1. Temperature detection check point 1 reduce from
Temperature detection starting check point ≤8°C,
the appliance keep heating and Open window
detection keep working.
2. Temperature detection check point 1 reduce from
Temperature detection starting check point > 8°C.
The appliance stop heating and standby, Open
window detection stop.(See Remarks)
3. Temperature detection check point 1(**°C) ≥
Temperature detection starting check point, the
appliance keep heating and Open window detec-
tion keep working
**°C: Maximum detection temperature 51°C(See
power-off protection)
11:00
Temperature detection check point 2(temperature
slow down detection check point)
1. Temperature at this point is end of this round
and start of next round.
2. Per 10 minutes as a round, in one round, detect
the temperature once every 5 minutes
3. At Temperature detection check point 2, test
method is the same as Temperature detection
check point 1.(compare with Temperature detec-
tion starting check point)
1. When the appliance stop heating, alarm 5s and fan keep
working 30s, then standby, set temperature mode light
flickering and LED displa
1.1 Press to restart to the same working mode before the
appliance stop.
After restart, Open window detection start a new time
round.
1.2 Press
to turn off, then LED display Environment
temperature and the appliance standby.
y OF and flickering.