Descargar Imprimir esta página

Craftsman 919.184190 Manual De Instrucciones página 22

Ocultar thumbs Ver también para 919.184190:

Publicidad

Idiomas disponibles

Idiomas disponibles

Before you store the air compressor,
make sure you do the following:
1.
Review the "Maintenance"
section on the preceding pages
and perform scheduled
maintenance as necessary.
2.
Set the On/Auto/Off
lever to
"OFF".
3.
Close the globe valve.
4.
Remove the air tool or accessory.
5.
Open the globe valve and allow
the air to slowly bleed from the
air tank until tank pressure is
approximately
20 psi.
6.
Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of air tank.
Water will
condense in the air
tank. If not drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture
and possible serious personal
injury.
7.
After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure.
The valve
can then be removed, cleaned, and
reinstalled.
8.
Protect the air hose from
damage (such as being stepped
on or run over).
D24917
22-ENG

Publicidad

loading