3. Remove the rivet pins and move the bellows up.
4. Examine the parts of the control levers for damage.
5. Examine the parking brake assemblies to make sure
that no parts are missing.
6. Replace all damaged or missing parts.
7. Push the control levers fully away from the seat.
8. Measure the clearance (A) between the interlock
bracket and the adapter with a feeler gauge. The
correct clearance is 0.030–0.060 in./0.75–1.5 mm.
 
C
B
 
9. Loosen the locknut (C) with a 1/2-in. wrench.
10. Set the correct clearance between the interlock
bracket and adapter.
a) Loosen or tighten the adjustment nut (B).
b) Measure the clearance.
c) Hold the adjustment nut (B) in the correct
position and tighten the locknut (C).
11. Engage and disengage the parking brakes a
minimum of 6 times to make sure that they operate
To engage and disengage the
correctly. Refer to
parking brake on page 12 .
2173 - 002 - 22.08.2023
A
12. Measure the clearance (A) between the interlock
bracket and adapter again.
13. Make sure that there is no tension in the parking
brake cables when the control levers are pulled fully
in the direction of the seat. Do not add tension to the
parking brake cables.
14. Install the bellows.
To charge the battery
Charge the battery if it is too weak to start the
Battery charging times on page 31
engine. Refer to
for battery charging times.
Use a standard battery charger.
CAUTION:
charger or start booster. A boost charger
or a start booster will cause damage to
the electrical system of the product.
Always disconnect the battery charger before you
start the engine.
To do an emergency start of the engine
If the battery is too weak to start the engine, you can use
jumper cables to do an emergency start. This product
has a 12 V system with negative ground. The product
that is used for the emergency start must also have a 12
V system with negative ground.
To connect the jumper cables
WARNING:
of explosive gas that comes from the
battery. Do not connect the negative
terminal of the fully charged battery to or
near the negative terminal of the weak
battery.
CAUTION:
product to start other vehicles.
Do not use a boost
Risk of explosion because
Do not use the battery of the
19