Product Details
PowerShareX PSX1204D/PSX2404D/PSX4804D
Front Panel (cover removed)
q w
e
r
ON
SDBY
CALL
PWR
CH1 CH2 CH3 CH4
q
Service port: For service only.
w
Power button: To switch between system On and Standby mode, press and hold for
three seconds. If desired, the operating condition can be modified by the
GPI/Remote (Remote On/Off).
e
Operating Mode LEDs: The LED will light green to indicate whether the amplifier is
On or in Standby mode.
LED
Light Color & Pattern
ON
Off
ON
Solid green
SDBY
Off
SDBY
Solid orange
SDBY
Blinking orange
Blink "counter"
SDBY
(pattern of blinks)
r
Callback button: Reserved for future use.
t
Soft Reset button: Resets network parameters to default settings (DHCP). Press
and hold for three seconds.
y
Hard Reset button: Restarts amplifier. Settings and loudspeaker EQs/presets are
unaffected. Can be used to cycle power when rear panel is inaccessible. Press and
hold for three seconds.
Note: To reset the amplifier to factory settings (DHCP), press and hold both the
Soft Reset and Hard Reset buttons for three seconds. This removes loudspeaker EQs/
presets and resets any adjusted settings.
u
Self Check button: For service only.
i
Channel Attenuation controls: Attenuation controls for the output level of each
channel. This affects analog inputs, Dante inputs, and pink-noise generator. Turn
the controls clockwise to decrease attenuation and counter-clockwise to increase
attenuation. Output level can also be adjusted with ControlSpace Designer.
Note: The attenuation control is in series with the Remote Level connector to limit the
output volume regardless of any remote adjustment.
4 • English
t y u
i
o
CLIP
-6dB/TEMP
SOFT
HARD
-12dB
CHECK
RESET
RESET
-24dB
SIGNAL
READY
ALARM
Note: Access the
front panel by
removing the left
faceplate and vent
filter. The faceplate
is secured by
magnets.
Indication
Amplifier is powered off
Amplifier is powered on
Amplifier is powered on
Amplifier is in standby mode
Amplifier is in auto-standby mode
Error code; contact Bose Professional
technical support
a
LIMIT
TEMP
CHECK
REMOTE
POWER ON
MAINS
ALARM
o
Channel Status LEDs: Status LED signal metering for Channels 1, 2, 3, and 4. See the
table below for details.
LED Name
Light Color & Pattern
CLIP
Orange
1
–6dB/TEMP
Solid yellow
Steady flashing
–6dB/TEMP
yellow
–12dB
Green
–24dB
Green
SIGNAL
Solid green
SIGNAL
Blinking green
READY
Solid green
READY
Blinking green
ALARM
Solid red
a
System Status LEDs: System status indicators. See the table below for details.
LED Name
Light Color & Pattern
LIMIT
Pulse flashing orange
LIMIT
Solid orange
TEMP
Solid yellow
CHECK
Solid orange
CHECK
Blinking orange
CHECK
Fast-blinking orange
REMOTE
Solid green
REMOTE
Off
POWER ON
Solid green
POWER ON
Off
MAINS
Solid green
MAINS
Off
MAINS
Pulse-flashing green
MAINS
Fast-blinking green
MAINS
Blinking green
ALARM
Solid red
Notes:
1.
Does not indicate signal clipping. View channel limiter activity in ControlSpace
Designer while on-line for channel limiting indication.
2.
Timing patterns of System Status and Channel Status LEDs:
Lighting
Timings
100 ms on
Pulse flashing
400 ms off
100 ms on
Steady flashing
900 ms off
100 ms on
Fast blinking
100 ms off
500 ms on
Blinking
500 ms off
PowerShareX PSX1204D/PSX2404D/PSX4804D • Installation Guide
BoseProfessional.com
PSX1204D
Signal
Other Indication
2
Metering
User
Channel limiter
Limiter
Thermal warning; thermal
–6 dB
is protection engaged
–6 dB
Standby
–12 dB
—
–24 dB
—
–60 dB
Signal presence
–60 dB
Channel is muted
—
Channel is ready
Amplifier is in
—
auto-standby
—
Channel fault
Indication
2
Breaker Save is enabled
Breaker Save is limiting power
draw
Thermal warning; thermal is
protection engaged
System is self-checking
Self-check is complete
Self-check is unavailable
Reserved for future use
—
System is ready
System is off
AC mains voltage is within
operating range
Under-voltage
Over-/under-voltage warning
Over-voltage
Blown mains fuses
PSU fault or critical faults