to moisture.
•Pull out from the basket all the removable
parts and dry them with a disposable towel.
Remount all the gaskets and reposition the
pieces on the machine.
•We recommend you alternate every 6
months the type of disinfecting agent to
avoid developing resistant forms of bacteria.
Bacteria spores are the most resistant
biological forms and, therefore, it is
recommended you use chloride-based
products.
TROUBLESHOOTING
•Machine does not cool:
•Check that the power plug is properly
inserted and the appliance has electrical
energy.
•The safety device of the compressor comes
into action: wait 5-10 minutes before
restarting the machine. Rapid and continued
start-up attempts do nothing but prolong the
period of inactivity of the machine.
•Check that the machine is correctly
positioned with the ventilation grids (6) free
of any obstructions.
•Check that the machine is not running a
preservation cycle (LED (11a,b,c,d) flashing)
that stops the compressor.
•Check that when the machine (switch (10))
turns on, the control panel shows the correct
initialization procedure by turning on all LEDs
in sequence.
•The paddle does not turn:
•Check that the paddle (5) is properly
attached to the tube and locked with a
special locking ring (4).
BLADE ACTIVATION
COMPRESSOR ACTIVATION
PROGRAMACTIVATION
CONSERVATIONACTIVATION
TURN OFFFROM PROGRAM
TURN OFFFROM CONSERVATION
PROGRAM CHANGE
CONSERVATIONCHANGE
PROGRAM ACTIVATION FROM CONSERVATION*
PROGRAM ACTIVATION FROM CONSERVATION***
* If conservation is activated after a program.
** To activate the program whose LED is flashing, first select a different program.
*** If conservation is activated without running programs.
14
English
ACTION
•Make sure it is free from obstacles that
prevent it from rotating.
•Make sure the lid is closed in the correct
position: a safety device stops the paddle
when the lid is opened.
•Check that the LED paddle (2a) is not
flashing. In this case, press the button (2)
twice to restart the paddle. Make sure that
the mixture is not too thick to prevent the
rotation of the paddle.
•Make sure that the machine is not running a
preservation cycle (LEDs (11a-b-c-d)
flashing) that stops the paddle.
•The machine is noisy:
•Some noise is part of the normal operating
specifications, but if it becomes excessive
contact the Service Centre to avoid further
and more serious problems.
•The water discharge pipe leaks:
•Replace the gaskets of the water discharge
tap (9). Two additional gaskets sets (16) are
provided with the machine. Lubricate the
gaskets before fit the tap (9) into the water
discharge tube.
•The plastic sleeve (17) on the lower part of the
paddle is too easy to separate.
•Replace the gasket with the new one. Four
additional gasket (15) are provided with the
machine.
•The paddle does not scrape properly the sides
of the bowl.
•Check that the scrapers (18) and (19) are not
damaged or worn.
•Check that the resilient pads (20) are not
distorted. If they are distorted replace them
with new parts. One set is included.
KEY COMBINATION
2
1
11
1+2 (3 seconds)
11 (3 seconds) then 1 and 2
11 (3 seconds)
11
12
11**
11