LIST OF PARAMETERS INDICATED BY 1
To gain access to the PHASE number press the MODE button once (an indicator light to the right of the
1
st
figure comes on). Press STEP to display all the available PHASES.
Example:
°
Phase n
1
Hot water temperature
2
Hot water system
Heating
3
4
Water delivery temperature
To exit the PHASE list press
st
FIGURE ON DISPLAY (Values can be adjusted by the user).
Step n°
display
Parameter
twice.
Parameter value
displayi
indicator light
Value range
from 60 to 90°C
00 = domestic hot water
excluded
01 = 5 °C hysteresis + pump
continuously on Hot water
02 = 5 °C hysteresis
03 = 10 °C hysteresis
04 = 20 °C hysteresis
05 = 30 °C hysteresis
00 = heating disabled
01 = heating enabled
02 = heating enabled, pump
running continuously
from 20 to 90 °C
45
Default settings
80
02
01
80