RESETTING
Should there be a fault the system will shut down and flash the fault type on the display.
Check for proper operating conditions (gas tap open, proper feed pressure etc.) and press RESET.
Should the fault persist contact your local LAMBORGHINI ASSISTANCE CENTRE.
PARAMETER DISPLAY AND MODIFICATION (ACCESS CODE)
By pressing MODE and STEP simultaneously the letter C will appear on the display. Keeping these
buttons pressed, enter the access code (62) by means of the + and – keys. Press STORE to memorise the
code (the display will flash twice). Press MODE to highlight the PHASE number on the display. Then
press STEP to display the list of PHASES.
°
Phase N
1
T
Hot water temperature
set
D.H.W. System (NTC3 absent)
2
Parameter
When setting has been
completed press
Range
From 60°C to 90°C (storage heater)
00 = Hot water off
01 = Hot water on + pump running
continuously with hysteresis of -5°C
on T
(Phase 1)
set
02 = Hot water on with hysteresis of -5°C
on T
(Phase 1)
set
03 = Hot water on with hysteresis of -
10°C on T
(Phase 1)
set
04 = Hot water on with hysteresis of -
20°C on T
.(Phase 1)
set
05 = Hot water on with hysteresis of -
30°C on T
.(Phase 1)
set
48