The following are the menus which can be modified:
P0 - Timer (MIN mode)
P1 - Timer (AUTO mode)
P2 - Timer (MAX mode)
A3 - Celsius and Fahrenheit
degrees
A4 - Offset
A5 - Battery saver value
A 5
Cut-out
0
20
1
20.3
2
20.6
3
20.9
4
21.2
5
21.5
6
21.8
7
22.1
8
22.4
9
22.7
Sleeping Well Back Plus_20220120
In MIN mode, the system's default setting is 6 hours of continuous operation.
The default value can be changed in this menu. The choice range is between 1
and 50 hours.
In AUTO mode, the system's default setting is 4 hours of continuous operation.
The default value can be changed in this menu. The choice range is between 1
and 50 hours.
In MAX mode, the system operates at its max power for the preset minutes. The
choice range is between 1 and 50 minutes. The system switches to the AUTO
mode.
The system's default setting is Centigrade degrees (C). This menu allows you to
change the parameter to Fahrenheit degrees (F).
This refers to the temperature difference detected by the probe and the tem-
perature shown on the display. This menu allows you to change this value from
-9°C to +9°C with 1°C increments
The default setting is 21.5 Vdc (Cut-out) and 24 Vdc (Cut-in). This menu allows to
change these values based on the following table. Values shown in bold are the
default ones.
2 4V D C
Cut-in
24.5
24
2 4V D C
A 5
Cut-out
10
20
11
20.3
12
20.6
13
20.9
14
21.2
15
21.5
16
21.8
17
22.1
18
22.4
19
22.7
Cut-in
24