▶ Everyone in the vicinity must wear ear protection, eye protection and a hard hat.
▶ Stay alert, watch what you are doing and use common sense when operating a direct fastening tool. Do
not use the fastening tool when you are tired or under the influence of drugs, alcohol or medication. Stop
working if you experience pain or feel unwell. A moment of inattention while operating the fastening tool
can result in serious injury.
▶ Avoid working in awkward body positions. Make sure you work from a safe stance and stay in balance
at all times.
▶ Keep the arms slightly bent while operating the fastening tool, do not straighten the arms.
▶ Keep other people away from the working area, especially children.
Use and care of direct fastening tools
▶ Use the fastening tool only for its intended use and only when it is in faultless condition. Do not attempt
to use the tool for purposes for which it is not intended.
▶ Do not use the fastening tool in places where there is a risk of fire and explosion.
▶ Before driving fasteners, check behind the object to make sure that no-one is present in line with the
fasteners to be driven. Danger of fasteners penetrating right through!
▶ Make sure that the nosepiece of the fastening tool is never pointed toward yourself or other persons.
▶ Hold the fastening tool only by the gripping surfaces provided for the purpose.
▶ Keep the gripping surfaces dry, clean and free from oil and grease.
▶ Pull the trigger only when the fastening tool is at right angles to and pressed fully against the work
surface.
▶ Before starting work, check the selected energy setting.
▶ Carry out a test by driving fasteners into the base material you are working on → page 25.
▶ When driving fasteners, always hold the fastening tool at right angles to the work surface. This reduces
the risk of a fastener being deflected by the base material.
▶ Do not drive fasteners into existing holes except in situations where this is recommended by Hilti.
▶ Do not re-use a fastener that was used beforehand - risk of injury! Use a new fastener.
▶ Do not attempt to re-drive a fastener that was not driven in deeply enough! The fastener could break.
▶ Never leave a loaded fastening tool unattended.
▶ Always unload the fastening tool (remove cartridges and fasteners) before cleaning, maintenance and
care, changing the fastener guide, before work breaks and before storing the tool.
▶ Transport and store the fastening tool in the Hilti case intended for the purpose.
▶ Store fastening tools that are not in use in a dry, secure place where they are inaccessible to children.
▶ Always position the nosepiece of the fastening tool on smooth, flat surfaces free of obstructions and fully
supported by the sub-structure.
▶ Comply with the specifications for distances from edges and spacing between fasteners (see the section
headed "Minimum distances" → page 23).
▶ Before driving fasteners, check that there is no electrical wiring, water piping or gas piping behind the
surface into which you want to drive them.
▶ For detailed information, request a copy of the Hilti 'Direct Fastening Technology Manual' or the
corresponding local Hilti 'Technical Guide to Fastening Technology' from your Hilti Store.
Thermal safety rules
▶ Do not exceed the maximum fastener driving rate recommended in the section headed "Technical data".
▶ If the fastening tool overheats or if the cartridge strip deforms or melts, remove the cartridge strip and
allow the fastening tool to cool down.
▶ Do not dismantle the fastening tool while it is hot. Allow the fastening tool to cool down.
Risk of explosion with cartridges
▶ Use only cartridges that are suitable and approved for use with the fastening tool.
▶ Remove the cartridge strip when you are going to take a break and when you have finished the job, and
before you transport the fastening tool.
▶ Do not use force to remove fasteners and/or cartridges from the magazine strip or the fastening tool.
▶ Store unused cartridges in accordance with the storage specifications for cartridges for powder-actuated
fastening tools (e.g. dry, temperature between 5 °C and 25 °C) in a locked storage facility.
▶ Do not leave unused or partly used cartridge strips lying around. Collect the used cartridge strips and
store the cartridge strips at a suitable location.
▶ Follow all instructions relating to safety, handling and storage in the safety data sheet of the cartridges.
20
English
2253453
*2253453*