Malfunction
The cartridge strip doesn't
advance
Cartridge strip is difficult to
remove.
The cartridge doesn't fire
The cartridge strip melts
A cartridge detaches itself
from the cartridge strip
10
Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
11
Manufacturer's warranty
▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
32
English
Possible cause
Wrong cartridge strip used
Fastening tool overheated.
Build-up of combustion residues.
Bad cartridge.
Fastening tool dirty.
Fastening tool was pressed against
the working surface for too long.
Fastener driving rate too high (fas-
tening tool overheated).
Fastener driving rate too high (fas-
tening tool overheated).
Action to be taken
▶ Use only cartridge strips of a
type intended for use with the
fastening tool.
▶ Allow the fastening tool to
cool down under constant
observation.
▶ Subsequently, carefully remove
the cartridge strip from the
fastening tool.
▶ Service the tool.
▶ Clean the cartridge chamber.
▶ Insert new cartridge strip.
▶ Pull the cartridge strip through
to the next cartridge.
▶ Service the tool.
▶ Remove cartridge strip and
insert a new cartridge strip
instead.
▶ Fire the fastening tool sooner
after pressing it against the
working surface.
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").
▶ Stop using the tool immediately.
▶ Remove cartridge strips and
allow the fastening tool to cool
down.
▶ Do not exceed the recom-
mended maximum fastener
driving rate (see the section
headed "Technical data").