2. Hold the fastening tool perpendicular to the working surface and then press it at right angles against the
surface.
3. Press the trigger to drive the fastener.
6.5
Unloading the single-fastener tool
1. Pull the cartridge strip up and out of the fastening tool.
2. Pull the fastener out of the fastening tool.
6.6
Driving X-FCM grating fasteners
1. Drive the threaded stud into the steel beam.
Use the centering sleeve to help ensure easy centering of the fastener.
2. Position the X-FCM retaining flange.
3. Follow the instructions in the installation instructions of the fastener.
6.7
Driving the X-FCP checker plate fasteners
1. Drill or punch the holes in the checker plate.
Observe the following minimum dimensions and distances:
A = 18-20 mm (0,70''-0,7'')
B ≥ 25 mm (≥ 0,98'')
2. Drive the threaded stud through the predrilled or punched hole.
3. Position the X-FCP retaining flange.
4. Follow the instructions in the installation instructions of the fastener.
6.8
Driving the X-GR grating fasteners
1. Insert the grating fastener into the fastener guide.
2. Drive the grating fastener through the grating into the supporting steel.
3. Follow the instructions in the installation instructions of the fastener.
6.9
Resetting the cleaning indicator
The cleaning indicator consists of 5 bars. Each bar stands for 500 fastenings.
The cleaning indicator is designed to indicate the correct cleaning intervals when the following
cartridges are used:
•
DX 6 cartridge titanium-gray
•
DX 6 cartridge, black
▶ Press the operating button at the display and hold it down for 10-12 seconds.
▶ The cleaning indicator is reset.
7
Troubleshooting
WARNING
Risk of explosion! Cartridges may fire (explode) if handled improperly.
▶ Do not use force to remove cartridges from the fastening tool or the magazine strip.
WARNING
Hazard due to hot surfaces! The fastening tool can become hot in use.
▶ Wear protective gloves.
26
English
13
12
11
2253453