Descargar Imprimir esta página

GYS GYSPOT ALU 66 Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
• Maintenance and repair of the power source may only be carried out by the manufacturer.
Any work undertaken by a third party on the machine will invalidate the warranty. The manufacturer will not be held responsible for
any incident or accident occurring after this work is carried out.
• Switch off the power supply by pulling the plug and wait two minutes before working on the equipment..
Inside the macine, the voltages and currents are high and dangerous.
• All welding tools suffer deterioration over time. Keep these tools clean to ensure that the machine performs at its best.
• Regularly remove the cover and blow out any dust.
Take this opportunity to have all electrical connections checked with an insulated tool by qualified personnel.
• Regularly review the condition of the power cable and welding connection cables.
In case of visible signs of damage, organise for them to be replaced by the manufacturer or a qualified technician.
• Keep the air inlet and outlet vents of the welding current source clean and clear.
POWER SUPPLY
• This equipment is supplied with a 16A CEE7/7 plug and must only be used on a single-phase 185 V to 265 V (50 -
60 Hz) three-wire electrical installation with an earth.
• The absorbed continuous current (I1p or ILp) indicated in the "Electrical data" section of this manual refers to the
maximum working capacity of the machine. Check that the power supply and its protection (fuse and/or circuit brea-
ker) are compatible with the current required to run the machine. In some countries, it may be necessary to change
the plug in order to use it at maximum capacity.
• Starting is done by pressing the I/0 switch (Fig. I-
Warning! Never switch off the power supply while the unit is under load.
Capacitor charging: the display flashes to indicate that the GYSPOT ALU is charging the capacitors to the
set value. If the capacitors are not charged, the message "DEF" is displayed. Switch the unit off and on
again. If the message persists, please contact GYS Aftersales service.
ELECTRICAL SPECIFICATIONS
Rated supply voltage U1N
Frequency
Rated open circuit voltage U2d
Continuous power Sp
Continuous supply current I1p
Maximum primary short-circuit current l1cc / ILcc
Maximum secondary short-circuit current I2cc
Continuous secondary current I2p
THERMAL SPECIFICATIONS
Ambient operating temperature
Ambient storage and transport temperature
DESCRIPTION OF THE UNIT (CF. PAGE 2)
This device is used to remove dents from aluminium bodywork by welding M4 & M6 aluminium studs, using capacitor
discharge. The capacitors have a rating of 66 millifarads.
Gun cable output (Fig. I-
Earth cable output (Fig. I-
The front of the device has a keypad with just 3 buttons (Fig. II)
It has a thermal fault LED (Fig. II-
The unit is equipped with a gun that has a 3m interconnection cable.
The 3 pins on the gun are used for grounding, and central support for the stud being welded.
M4 and M6 stud types: Alu magnesium (AlMg3) or Alu silicon (AlSi12)
When the unit is switched on, an error message may appear indicating that the trigger on the gun has been held down.
It is possible that the button is stuck or has short-circuited. In either case, please contact your distributor.
12
GYSPOT ALU 66
)
1
)
2
)
5
), and stopping is done by pressing the same switch (0).
3
1 ~ 185 - 265 V
50 - 60 Hz
50 - 200 V
0.52 kVA
0.7A / 4.5 A
6.5 A
13000 A
4.4 A
From +5°C to +40°C
From -25°C to +55°C
EN

Publicidad

loading

Este manual también es adecuado para:

080188