Piping Methods To
Connect Appliance
To Gas Supply
A TRAINED SERVICE
TECHNICIAN
OR GAS
APPLIANCE
INSTALLER
MUST MAKE THE GAS
SUPPLY CONNECTION.
Leak testing of the
appliance
shall be conducted
by the installer
according to the instructions
given.
Unless prohibited by local codes or ordinances, a new
A.G.A. - Certified, flexible metal appliance connector may
be used to connect this appliance to its gas supply. The
connector must be no more than 5 feet in length. Per
figure 5, use appropriate flare union adapter at each end
of the flexible connector. If a flexible connector is used
assure that both the appliance pressure regulator and
manual shut-off valve are joined solidly to other
permanent hard piping (either gas supply or the appliance
manifold) so as to be physically stationary. See
illustrations below.
Apply a non-corrosive leak detection fluid to all joints and
fittings in the gas connection
between the supply line
shut-off valve and the range. Include gas fittings and
joints in the range if connections were disturbed during
installation. Check for leaks! Bubbles appearing around
fittings and connections
will indicate a leak. If a leak
appears, turn off supply line gas shut-off valve, tighten
connections, turn on the supply line gas shut off valve,
and retest for leaks. Never test for gas leaks with an open
flame.
Pressure
Testing
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply piping
system at test pressures equal to or less than 1/2 pounds
per square inch (3.5 kPa).
This appliance, as well as its individual shut-off valve,
must be disconnected from the gas supply piping system
during any pressure testing of the system at test
pressures in excess of 1/2 pounds per square inch (3.5
kPa).
When checking appliance regulator function, make certain
pressure of natural gas supply is between 6 and 14
inches of water column or, if converted for LP gas,
between 11 and 14 inches of water column.
ILLUSTRATIVE
ALTERNATIVE
PIPING
Entrance
I
I
I
_
"ql'--- Appliance Pressure
/_
Regulator, Supplied
,,,,_
_"'_1111
J/
(Observe directionality
.._li_,,,,_:_)
of G as F low)
_
- -I,
'_
_"
t
3/8" N,P,T,
_
FlareUnion
Elbow
u'_"-'_-
Flare UnionAdaptor
_
Adaptor
_[_
"_f!-_
_1.- 318"N.P.T.Flexible
1/2" N.P.T.Flexible
_,_
_
ApplianceConnector
_
A5pfpt iance.)C onnector
._
(5 ft. max.)
I
1;_1-
Flare Union Adaptor
I
1-Gas Shut-Off Valve
I
"91--1/2"
N.P.T. Pipe
(Stationary Supply Pipe)
NO APPLIANCE
MOUNTED BELOW
THIS COOKTOP
WALL OVEN MOUNTED
IN CABINETRY BELOW
THIS COOKTOP
I
_1_ _1- Flare Union
Adaptor
I
-,ql-- ppliance Pressure
Regulator, S upplied
(Observe
directionality of Gas
I
Flow)
1_1/2" N.P.T. Pipe
Nipple
I
Gas Shut-Off Valve
I
-112" N.P.T.Pipe
(StationarySupply
Pipe)
FIGURE5