Descargar Imprimir esta página

Maytag MGC5430 Manual De Instalación página 9

Ocultar thumbs Ver también para MGC5430:

Publicidad

Idiomas disponibles

Idiomas disponibles

B. INVERT CAP IN APPLIANCE
PRESSURE
REGULATOR (See figure 11)
With the appliance installed, the appliance regulator
should be located as shown in figure 3, 4 or 5.
CONVERSION
OF APPLIANCE
PRESSURE
REGULATOR
APPLY D OWNWARD
FINGER PRESSURE
ATDISC EDGES TO
R_r_Lp
REPLACE
PIN INCAP.
CONVERTE
APPLY S IDEWARD
_., CAP
I
_
FINGER
PRESSURE
_"=
AND PIN
J
TOREMOVE PIN
./"
(_
FROM CAP
NAT i
/'_
NAT
I
I LP
L+_
--
_
I
I
FIGURE 11
C. LOW FLAME ADJUSTMENT
(See figure 12)
This appliance is shipped from the factory with low and
high flame settings adjusted for use with natural gas.
To set for use with LP proceed as follows:
1. Remove control knob from valve stem.
After adjusting the screw the burner should produce a
stable, steady blue flame of minimum size. The setting
should be checked by turning knob from high to low
several times without extinguishing the flame.
This operation will automatically provide the proper flame
size at medium setting.
After Conversion Steps A, B and C have been completed,
check the appearance of each burner flame at the Hi and
Lo settings against figure 13. If the flames appear too
large or too small, review each step to make sure it was
completed correctly.
FLAME
APPEARANCE
AT HI AND
LO
2. Carefully remove rubber grommet.
3. Locate the valve adjustment screw. See figure 12.
4. Insert a slender, thin-blade screwdriver into knob
hole and engage blade with slot in adjusting screw.
5. Turn the adjusting screw clockwise until tight (5-7
in-lbs max.). Do not over tighten.
6. Replace rubber grommet and control knob.
7. Repeat for remaining burners.
KNOB
ADJUSTI_
,
SCIEW
I]
(KNOB AND GROMMET
REMOVED)
FIGURE 12
FIGURE 13
IIO0
OO0$
High Altitude Notice
The specified gas burner ratings typically apply to
elevations up to 2000 feet. For higher altitudes, the rates
may need to be reduced to achieve satisfactory operation.
A local certified gas servicer will be able to advise if a
reduction is necessary.