Safety and Usage Information
2
2.1 Your Scale and Its Environment
2.1.1 Working Environment
To ensure your safety as well as the service life of your scale, please avoid using the scale under the following circumstances:
Concurrent use of this device and implantable medical electronic instruments, e.g. Cardiac Pacemaker.
Concurrent use of this device and wearable medical electronic instruments, e.g. electrocardiograph.
Concurrent use of this device and other medical electronic instruments for life support, e.g. mechanical heart.
Slippery floor such as tile floor.
Jumping onto the platform immediately
Operating Instructions
3

3.1 Insert the Batteries

Open the battery door in the back of the scale.
Insert the batteries (2 x 3V CR2032) into the battery compartment according to the polarity indications marked inside the
compartment.
* The LCD will display in full screen.
Close the battery door and wait until the digits "0.0kg" are shown on the LCD.
3.2 Set Up Your Profile
The body fat analyzer Scale 300 supports multiple users (Up to Eight). You may follow below instructions to assign User ID and
set up your own profile, including Gender, Stature, and Age.
3.2.1 Assigning User ID
The system will request User ID selection first.
As pictured below, "P1" blinks. The operator may press the function key
to select User ID.
Press "SET" key to confirm User ID.
3.2.2 Setting Gender
After confirming User ID, the system will
divert to Gender setting automatically.
As pictured below, the portrait
blinks. The
operator may press the function
key
or
to select Gender.
Press "SET" key to confirm Gender.
3.2.3
Setting Stature
After confirming Gender, the system will divert to Stature setting automatically.
As pictured below, the digits "100" blinks. The operator may press the function
key
or
to increase or decrease the numeral (Range: 100cm-220cm).
You may press and hold the function k key
Press "SET" key to confirm Stature.
3.2.4 Setting Age
After confirming Stature, the system will divert to Age setting automatically.
As pictured below, the digits "10" blinks. The operator may press the function
key
or
to increase or decrease the numeral (Range: 10-80 years old).
You may press and hold the function key
Press "SET" key to confirm Age. When the LCD displays "0.0kg", you may start
measuring.
3.3 Select Measurement Unit
Press "UNIT" button in the back of the scale to select measurement
unit. The default measurement unit is "kilogram". You may press
"UNIT" button to choose among kilogram, stone and pound.
4
or
Man
Woman
Sportsman
Sportswoman
or
for fast changing the numeral.
or
for fast changing the numeral.
Measure in Kilogram / Centimeter
Measure in Stone / Foot
Measure in Pound / Foot
3.4 Start Measuring
3.4.1 First Measurement
After confirming Stature, the system will divert to Age setting automatically.
As pictured below, the digits "10" blinks. The operator may press the function
key
or
to increase or decrease the numeral (Range: 10-80 years old).
You may press and hold the function key
or
for fast changing the numeral.
Then the measuring results will be displayed sequentially for three times: Body Fat, Total Body Water, Muscle Mass, Bone
Mass.
If it fails to complete the analysis, the LCD will only display the weight data.
(To find out the solutions, please refer to 5 Troubleshooting for more details.)
The Scale 300 will shut off automatically then.
3.4.2 Daily Measurement
With original SENSE ON patent technology, the Scale 300 will automatically switch on as you step on the platform
barefooted.
The LCD will first display your weight and then moving "o", indicating the analysis is proceeding. Please stand still and keep
full contact with the electrodes until the LCD stops displaying moving "o".
According to the analysis results, the system will automatically identify the possible User ID with most similar history
records. Then the measuring results will be displayed sequentially for three times.
When the system finds out two or more users with similar history records, it will notify you to choose between, for
example, P2 and P4. You may press
key for P2 and or
User ID you selected and displayed sequentially for three times.
If it fails to identify the possible User ID, the LCD will only display the weight data. (To find out the solutions, please refer to 5
Troubleshooting for more details.)
THE SCALE 300 will shut off automatically then.
3.4.3 Body Fat Level Indicator
Your body fat level will also be displayed when the measuring results are
shown on the LCD.
(Please refer to 9.1 Table of Body Fat Level for more details.)
As pictured below, the user's body fat level is LOW.
Table of Body Fat Level (Unit: %)
Man / Sportsman
Age
Low
Normal
High
V. High
< 39
< 8
8.1 - 20
20.1 - 25
> 25
40-59
< 11
11.1 - 22
22.1 - 28
> 28
> 59
< 13
13.1 - 25
25.1 - 30
> 30
EN
key for P4. The measuring results will then be sorted into the
Woman / Sportswoman
Low
Normal
High
V. High
< 21
21.1 - 33
33.1 - 39
> 39
< 23
23.1 - 34
34.1 - 40
> 40
< 24
24.1 - 36
36.1 - 42
> 42
5