Troubleshooting
4
4.1 Error Prompt
Error
Description
Overload.
Low Battery. The device will power off in
four seconds.
Body Fat Percentage is out of the measu-
rement range.
4.2 When Measuring ...
Problem
Root Cause
Incorrect posture.
The device is located on the soft ground
such as a carpet OR on a rugged surface.
Abnormal measuring results:
Cold body that may results in bad blood
- Too high; OR
circulation
- Too low; OR
- Huge difference between two
Cold Electrodes
recent measurement.
Either your hands or your feet are too
dry.
Batteries not yet installed.
No display on LCD when the
device powers on.
Worn batteries.
Step onto the platform wearing socks or
shoes.
CANNOT proceed to analyze body
The system cannot identify the possible
fat, total body water, muscle mass
User ID with most similar data.
and bone mass.
The user fails to select the User ID from
what the system found.
The device powers off automati-
Low battery.
cally.
Specifications
5
Scale
Dimension
Panel
Measurement Unit
Kilogram / Pound / Stone
Measurement Range
5kg to 150kg / 11lb to 330.6lb / 0st:11lb to 23st:8lb
Division
0.1kg / 0.2lb(Weigh <20st: division is 0.2lb;Weigh >=20st: division is 1lb)
0 - 50kg: ± 0.3kg
Accuracy
50 -100kg: ± 0.4kg 100 -150kg: ± 0.5kg
Temperature
Working Environment
Humidity
Storage Environment
Temperature
Power Source
6V (2 x CR2032 Lithium Battery)
8 to 12 seconds after clearing
Auto-OFF
Otherwise, 30-42 seconds after last operation
6
Solution
Stop using this scale for
measurement.
Replace all four batteries in the same time.
Stop using this scale for
measurement.
Solution
Please step on the platform barefooted and stand still.
Please place the device on a flat, hard surface.
Warm up your hands and feet to resume blood circulation and
then measure again.
Place the device in a warm room for a while and then measure
again.
Wipe your feet with a damp cloth, keeping them slightly
damp when starting measurement.
Install the batteries.
(Please refer to 3.1 Insert the Batteries)
Replace all batteries in the same time.
Please keep barefooted during the measurement, and keep
full contact with the electrodes as well.
Please assign a User ID following the instruction in 3.2 Set Up
Your Profile.
Please assign a User ID following the instruction in 3.2 Set Up
Your Profile.
Replace all batteries in the same time.
310mm(L) x 310mm(w) x 24.5mm(H)
310mm(L) x 310mm(W) x 6mm(H)
0° to 40°
≤90% RH
- 20° to 60°
1
Présentation
1.1 Produit
Touche
Électrode
Compartiment de batteries
1.2 Écran LCD
Symboles d'affichage
ID utilisateur (entre P1 et P8)
Homme
Femme
Sportif
Sportive
Résultat de l'analyse de corps gras
Résultat de l'analyse de l'eau totale dans
le corps
Résultat de l'analyse de masse muscu-
laire
Résultat de l'analyse de masse osseuse
Niveau de masse grasse : Bas
FR
Écran LCD
Touche
Électrode
Touche configuration
Touche unité
Pied
Centimètre
Pierre
Livres
Kilogramme
Pourcentage
Âge
Niveau de masse grasse : Normal
Niveau de masse grasse : Haute
Niveau de masse grasse : Très haute
7