Performance
SmartWater
TM
Data Sheet
Filtration System GE
MWF Cartridge
The concentration of the indicated substances inwater entering the system was reduced to a concentration lessthan or equal to the permissible
limit for water leaving the system as specified in NSF/ANSl S tandard/42 and Standard 53. Systemtested and certified by NSFInternational against
NSF!ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity
300 Gallons 11,135 Liters).
Substance Tested
for Reduction
AverageInfluent
2.0 mg/L
7,833,333
pts/mL
101,000 cysts/L
47 MF/L
@009 mg/L
@016 mg/L
@08 mg!L
@007 mg/L
0.152 mg/L
0.148 mg/L
0.002 mg/L
0.0058 mg/L
0.0061 mg/L
0.222 mg/L
0.015 mg/L
0.015 mg/L
0.218 mg/L
*Basedon the useof Cryptosporidium parvum oocysts.
Contaminant
Reduction
Determined
NSFspecified
Challenge Concentration
2.0 mg/L _+10%
At least 10,000 particles/mL
Minimum
50,000 cysts/L
107 to 108 fibers/L; fibers
greater than 10 tim in length
0.009 mg/L _+10%
0.015 mg/L _+10%_+
0.08 mg/L _+10%
0.006 mg/L _+10%
0.15 mg/L _+10%
0.15 mg/L _+10%
0.002 mg/L _+10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.225 mg/L _+10%
0.01S mg/L _+10%
0.015 mg/L _+10%
0.210 mg/L _+10%
Avg %
Reduction
97.5%
99.7%
99.99%
>99%
94.5%
9@7%
98.7%
97.1%
993%
993%
99.0%
932%
932%
99.8%
96.7%
932%
99.5%
_y NSF testing.
Average Product
Water
Concentration
0.05 mg/L
18,617 pts/mL
1 cyst/L
<1 MF/L
0.0005 mg/L
0.0005 mg/L
0.001 mg/L
0.0002 mg/L
0.001 mg/L
0.001 mg/L
0.00002 mg/L
0.000/4 mg/L
0.000/4 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.0009 mg/L
Max Permissible
Product Water
Concentration
N/A
N/A
N/A
N/A
0.003 mg/L
0.005 mg/L
0,0/4 mg/L
0.002 mg/L
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
0,07 mg/L
NSF Reduction
Requirements
> 50%
>85%
>99.95%
->99%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
NSF
Test Report
J-00077703
J-0007770/4
J-00100036
J-00077707
J-00077708
J-00077717
J-00077718
J-00100039
J-00077722
J-00077723
J-00077726
J-00100037
J-00092355
J-00077729
J-0008218/4
J-00077730
J-00085/470
The following
pharmaceutical
reduction
claims have not been certified
by NSF International
or the state of California.
Claims tested and verified
by independent
laboratory:
Contaminant
Reduction
Averagelnfluent
978 ng/L
907 ng/l
885 ng/L
1097 ng/L
/415 ng/L
NSFspecified
Challenge Concentration
N/A
N/A
N/A
N/A
N/A
Avg %
Reduction
99.5%
99./4%
9/4.1%
99.5%
99.5%
Average Product
Water
Concentration
5.0 ng/L
5./4 ng/L
52.3 ng/L
5.0 ng/L
2.0 ng/L
Max Permissible
Product Water
Concentration
N/A
N/A
N/A
N/A
N/A
NSF Reduction
Requirements
N/A
N/A
N/A
N/A
N/A
NSF
TestReport
J-00121587
J-00121587
J-00121588
J-00121589
3-00121587
Application
Guidelines/Water
Supply
Parameters
Service Flow
0.5 gpm {21.9 Ipm)
Water Pressure
/40-120
ps (2 8-8 2 bar)
Water Supply
Potable Water
Water Temperature
55°F-100°F (0.6°C-38°C)
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note:
While the testing was performed
under standard laboratory
conditions,
actual performance
may vary.
Replacement
Cartridge: NWR For estimated
costs of replacement
elements
please call 1-800-626-2002
or visit our website at www.geapplianceparts.com.
AWARNING
To reduce the risk associated
with ingestion of contaminants:
• Do not use with water
that is microbiologically
unsafe or of unknown quality
without
adequate
disinfection
before and after the system. Systems certified
for cyst reduction
may be used on disinfected
water that may contain filterable
cysts. EPA Establishment
Number 10550-MN-005,
For conditions of use, health claims certified by the California Department
of Public
Health, and replacements,
see performance
data sheet. California Department
of Public Health Certification
#05&698.
The contaminants
or other substances
removed or reduced by this water filter are not necessarily in all users' water.
NOTICE
To reduce the risk associated
with property
damage
due to water leakage:
, Read and follow use instructions
before installation
and use of this system.
• Installation
and use MUST comply with all state and tocal plumbing
codes.
• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure
exceeds 80 psi. you must install a pressuredimiting
valve. Contact a plumbing
professional
if you are uncertain
how to check your water pressure.
• Do not install where water hammer conditions
may occur. If water hammer
conditions exist you must install a water hammer arresten Contact a plumbing
professional
if you are uncertain
how to check for this condition.
, Do not install on hot water supply lines. The maximum
operating water
temperature
of this filter system is 100 ° F (380 C).
, Protect filter from freezing. Drain filter when temperatures
drop
below 33°F (0.6°0.
• The disposable
filter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable
reduction
in flow rate occurs.
/_i_d'_£_
Tested and certified by NSFInternational
}_1_';
against NSF/ANSIStandard 42 and
1_'
Standard 55 in n]odel GEHWF f0r the
reduction of the claims specified on the
_E_t_CE_"I