Descargar Imprimir esta página

STEINEL XSolar SOL-O S Manual Del Usuario página 12

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 29
• Affix house numbers to illuminated panel. (Fig� 4�1)
• Mark drill holes with the aid of a spirit level. (Fig� 4�2)
• Drill holes and insert wall plugs (Fig� 4�3)
• Tightly screw wall mount in place (Fig� 4�4)
• Settings ➔ "5� Operation"
• Make settings (Fig� 5�1 + 5�5)
Fit base on wall mount (Fig� 4�5)
5� Operation
Before using for the first time
• XSolar SOL-O S: 
Activate light by setting the programme selector switch
to P3. The light stays in test mode for one minute before
it starts to work in programme P3.
• XSolar SOL-O: 
Activate light by setting the programme selector switch
to P2. The light stays in test mode for one minute before
it starts to work in programme P2.
Test mode
During the test sequence the light works in daylight mode.
On detecting movement, the light switches ON for 1 minute
with a stay-ON time of 10 seconds, irrespective of light-
level setting. The programme is automatically activated
after this time elapses.
The red LED stays ON all the time in test mode.
XSolar SOL-O S
Setting the chosen operating mode by programme
selector switch (Fig� 5�1)
– P0: OFF (factory setting).
The light is deactivated.
– P1: Sensor mode.
The light switches ON after detecting movement.
– P2: Sensor mode with night light.
The light switches ON after detecting movement. Light
permanently ON in the morning and evening hours at
reduced night light level.
– P3: Illumination of house numbers and sensor mode.
At night, house numbers are illuminated at reduced night
light level. Light switches ON after receiving a signal from
the motion detector. If the battery charge is low, house
number illumination has priority over the main light. This
means night light is active but the light does not switch ON
in response to movement.
Stay-ON time and brightness
– Stay-ON time is determined when the light is used for
the first time.
– During the first night, night light is switched OFF in the
morning in programme 2.
– Stay-ON time and brightness are automatically matched
to ambient conditions, e.g. stay-ON time may be longer
in summer than it is in winter.
– Night light provides illumination at night of approx. 3 %
light output. Light is switched to maximum output when
movement is identified in the detection zone.
The light then switches back to night light (approx. 3 %).
Using night light reduces light availability. If it is not needed,
we recommend switching it OFF (P1) to ensure lighting
availability in less sunny periods.
110073820_STE_XSolar SOL-O S_SOL-O_HN.indd 12
110073820_STE_XSolar SOL-O S_SOL-O_HN.indd 12
Adjusting the detection zone (Fig� 5�2, Fig� 5�3, Fig� 5�4)
The detection zone can be limited to suit requirements.
The shrouds supplied with the unit can be used to mask
out as many lens segments as you wish. This prevents
the light from being activated unintentionally, e.g. by cars,
passersby etc., and allows you to target danger spots. The
shrouds can be cut along the grooved vertical divisions.
Then you simply clip them onto the lens.
XSolar SOL-O / XSolar SOL-O HN
Setting the chosen operating mode via programme
selector switch (Fig� 5�5)
– OFF: (factory setting).
The power consumers (LEDs) are deactivated.
– P1: evening mode.
The luminaire activates constant illumination when
ambient light falls below the light level threshold (2 lux)
and automatically switches it OFF again after approx.
4 h. Light is adjusted to optimum brightness for the level
of battery charge.
– P2: night mode.
The luminaire activates reduced constant illumination
when ambient light falls below the light level threshold
(2 lux) and automatically switches it OFF again at dawn.
Light is adjusted to optimum brightness for the level of
battery charge.
6� Charging the battery manually
The red LED in the motion detector or light flashes if battery
capacity is too low ( e.g. in poor weather ).
The battery can be recharged with a standard micro USB
charging adapter, e.g. a mobile phone charging cable ( not
included ). The battery can take up to 6 hours to recharge.
• Separate base from wall mount with the twist of a
screwdriver. (Fig� 6�1)
• Detach USB protection. Connect micro USB
charging adapter (Fig� 6�2)
– Red LED flashing: charging in progress.
• The LED may take up to 10 minutes to start flashing if
the battery has run down to very low level.
– Red LED on: battery is fully charged.
• Remove micro USB charging adapter.
– Red LED goes out.
• Fit base on wall mount (Fig� 4�5)
7� Maintenance / care
The product requires no maintenance.
Regularly checking the product for damage can prolong its
lifespan. Removing dirt can prolong the product's lifespan.
If the solar panel is dirty or weather has left deposits on it:
• Clean solar panel with a soft cloth and mild detergent.
- 12 -
06.11.23 16:40
06.11.23 16:40

Publicidad

loading

Este manual también es adecuado para:

Xsolar sol-oXsolar sol-o hn