9
ERROR CODES
It is important to troubleshoot any faults in the electronic control system of your product as soon as possible to
ensure safe and proper operation. The error codes listed in the manual provide a helpful guide for identifying and
resolving any issues. Below are the detailed definitions and solutions for each error code.
Error code
Definition
E001
Controller Abnormality
E002
Communication Abnormality
E003
Motor Hall Signal Abnormality
E004
Throttle Abnormality
E005
Brake Abnormality
E006
Motor Phase Abnormality
E012
Battery Voltage Abnormality
10
TECHNICAL DATA
Voltage
Max. payload
Minimum rider age
Maximum speed
Maximum slope
Battery model
Charger model
The recommended ambient temperature range:
Item
Product storage temperature range
Product operation temperature range
Battery charging temperature range
Charger operation temperature range
Battery storage temperature range
Battery discharging temperature range
11
LIMITED WARRANTY
®
greenworks
products are warrantied against all
defects in materials, parts, or workmanship under
normal use for a period of 18 months from the shipping
date or in-store purchase date.
At its own discretion, greenworks
replace, substitute with a comparable item, or issue a
refund for products that are determined to be defective
English (Original Instructions)
®
can opt to repair,
Solution
Contact dealer for assistance.
Check the motor plug. If everything is in order, contact
dealer for assistance.
Contact dealer for assistance.
Check whether the throttle is in place. If everything is in
order, contact dealer for assistance to replace the throttle.
Check whether the brake is in place. If everything is in
order, contact dealer for assistance to replace the brake
lever.
Contact dealer for assistance.
Use the battery with the correct voltage.
80V DC
300 lbs. (136 kg)
14 years old
20 mph (32 km/h)
10°-12°
BAB742 and other BAB series
2901402 and other CAB series
Temperature
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 104°F (40°C)
39°F (0°C) - 104°F (40°C)
39°F (0°C) - 104°F (40°C)
32°F (0°C) - 113°F (45°C)
32°F (0°C) - 104°F (40°C)
through normal use or that have been damaged during
shipment. Proof of purchase and product registration
is required. Replacement of products or parts subject
to normal wear and tear is the responsibility of the
customer.
This warranty is valid only for units which have been
maintained in accordance with the instructions found in
the operator manual supplied with the product; and for
units which have been registered in one of the following
ways:
21
EN

Publicidad

loading

Este manual también es adecuado para:

7422102