1. FIRST ACTIVATION AFTER VEHICLE CONNECTION
1. To activate the device, after battery connection, turn ON and OFF the vehicle instru-
ment panel.
2. The alarm unit emits 2 BEEP + 2 BOOP and LED start fl ashing quickly, within 1 minute
activate the instrument panel, the alarm unit emits 2 BEEP + 2 BOOP again and activa-
tion will be completed; if the instrument panel activation don't occur within 1 minute
the activation will be automatically and the alarm unit emits 2 BEEP + 2 BOOP to advise
about it.
NOTE: Whenever the vehicle battery will be connect (for example after disconnecting it for winter
period or maintenance) to activate the device, repeat steps 1 and 2 above.
The CARD B9.5 supplied in the package are not active. To activate them press it's button 5 times.
After turned OFF the vehicle instrument panel the alarm unit will be ready to arming, the com-
plete arming will happen 20 second after moved the CARD B9.5 out of the detection range, ar-
ming is signaled by a 2 BEEP sounds, 2 fl ashes of direction indicators and a quick fl ashing of the
LED to indicate start of immunity time during that is possible check all the protection without
triggering an alarm sounding (see chapter "6. IMMUNITY TIME").
After immunity time all the alarm protections will be ready to produce an alarm trigger and the
LED will fl ash slowly.
4. ARMING BY THE CARD B9.5 BUTTON
Press briefl y the CARD B9.5 button close to the vehicle. Releasing button the alarm unit will
arming and it will be signaled by 2 BEEP sounds, 2 fl ashes of direction indicators and a quick
fl ashing of the LED to indicate start of immunity time during that is possible check all the pro-
tection without triggering an alarm sounding (see chapter "6. IMMUNITY TIME").
After immunity time all the alarm protections will be ready to produce an alarm trigger and the
LED will fl ash slowly.
5.
ARMING WITHOUT ACTIVATING THE INTERNAL MOVEMENT SENSOR
Press hold the CARD B9.5 button for 6 seconds close to the vehicle. Releasing button the alarm
unit will arming and it will be signaled by 2 BEEP+1BEEP sounds, 2+1 fl ashes of direction indi-
cators and a quick fl ashing of the LED to indicate start of immunity time during that is possi-
ble check all the protection without triggering an alarm sounding (see chapter "6. IMMUNITY
TIME").
After immunity time all the alarm protections will be ready to produce an alarm trigger and the
LED will fl ash slowly.
During the fi rst 26 seconds after the alarm arming, the LED fl ashing quickly to indicate that it is
possible to test the protection functions of the system.
Every alarm triggers doesn't produce an alarm sounding but just a BEEP sounds by the siren and
the reset of initial immunity time that restarts again.
When immunity time is over, the LED fl ashes normally and every alarm triggers will produce an
alarm sounding.
KTM | DEFCOM 3.1B User Manual
2. CARD B9.5 ACTIVATION
3. AUTOMATIC ARMING
6. IMMUNITY TIME
9