Long-press the TEST/HUSH button.
The green LED will light up, the red LED will be flashing and the alarm will be beeping.
Use test mode 1× a week.
FAULT STATE
If the detector is in fault state, it is not functional.
Fault state is indicated by 1 beep every 30 seconds and the green and yellow LED will be lit up.
Disconnect the detector from the mains and reconnect it after a few moments.
Perform a functionality test.
If the detector still does not work, contact a service centre.
END OF DETECTOR SERVICE LIFE
The detector has a service life of 5 years since production.
After expiration, the detector must no longer be used and must be replaced with a new device.
The date for replacing the detector is listed on the front of the detector under the TEST/HUSH button.
If you are using multiple detectors, remember to check their replacement dates!
ALARM WARNING
If gas is detected, the green LED will light up and the red LED will be flashing.
A siren will be beeping at the same time.
To silence the siren, press the TEST/HUSH button; the siren will be silenced for 5 minutes.
Then the alarm siren will reactivate.
In the event of an alarm, proceed as follows.
Extinguish all open flames.
Turn off all gas appliances.
Do not turn any electrical appliances on or off, including the detector itself.
Shut off the gas supply and the main shutoff valve.
Open the windows and doors.
Do not use a mobile phone while in the building where the gas leak is likely to have occurred.
Inform people in the vicinity (do not ring the bell to alert your neighbours, only knock).
If the alarm is still active and the cause of the gas leak has not been found, leave the building
and immediately contact the gas supplier's emergency breakdown service. Or contact the fire
brigade or the police.
Upkeep and Maintenance
The product is designed to serve reliably for many years if used properly. Here are some tips
for proper operation:
• Read the manual carefully before using this product.
• The product must be replaced with a new one after 5 years – see replacement date
on the front.
• Regularly clean the product – at least 1× a month.
• Carefully clean any dirt and dust from ventilation openings of the product with a vacuum
cleaner.